Skip links

TLA100

Tank Level Adapter

* TLA100 may require configuration depending on application, see User Manual (Maretron DSM570, DSM410, USB100, or IPG100 needed to configure)

Link to knowledge base and frequently asked questions

Is this the correct tank monitor for my application?

Follow this Link for a Knowledge Base Article describing which product to use for your particular Tank Monitoring Application.

The TLA100 is used to adapt commercially available resistive tank senders to NMEA 2000® network. This allows you to observe tank levels anywhere on the vessel where there is an NMEA 2000® compatible display such as Maretron's N2KView® vessel monitoring system, or Maretron's DSM570 / DSM410 color graphics displays.

The TLA100 is compatible with both the American standard (240-33 ohm) and the European standard (10-180 ohm) resistive senders. In fact, the TLA100 can be calibrated for any resistance between 0 and 300 ohms.

Unlike most tank senders that only work with rectangular tanks, the TLA100 can be calibrated for irregular tank shapes so you know the true level of the tanks. You can also use the TLA100 with analog gauges so you don't have to get rid of existing gauges to enjoy the advantages of digitally networked information.

  • Tank Level
  • Tank Capacity
  • Fluid Type
  • Fuel Tanks
  • Fresh Water Tanks
  • Grey Water Tanks
  • Black Water Tanks
  • Live Well Tanks
  • Oil Tanks

Note: Maretron monitoring sensors are updated using Maretron’s N2KAnalyzer application on a PC paired with an approved NMEA 2000® gateway.

2.1.2.2 (2017-09-12) – Current Release (HW 2.0)
  • Support Heartbeat PGN (126993)
  • Support variable transmission settings
  • Correctly support N2K Level A protocol
  • Comply with NMEA2000 version 2.100 certification
  • Change NMEA Certification Level to 2
  • Miscellaneous sw enhancements

2.0.2.3 (2016-08-09)
  • Correct fluid source transmitted in Channel PGN (Bug #3959)
  • Correct lost instance issue (Bug #3964, # 3965, #3966, #3967, #3968)

2.0.1.5 (2015-06-03)
  • Support TLA100 HW 2.0 (TLX100 HW 2.0 PCB) (STM32 platform) (Not compatible with HW 1.0)

 

1.7.2.8 (2014-10-29)
  • Added feedback to calibration to indicate resistance during calibration (Bug #2007)
  • Changed NMEA 2000 Database version to 2.000 (Bug #2628)
  • Filled unused character in fixed length strings of N2K PGN with 0xFF (Bug #993)

 

1.7.0.1 (2013-09-20)
  • Fixed problem where writing label or gauge resistance would interfere with each other (they accidentally shared storage space) (Bug #2085)

 

1.6.15 (2009-08-10)
  • Added capability to be configured by N2KAnalyzer

 

1.6.14 (2009-03-20)
  • Fixed problem with custom calibration introduced in 1.6.13

 

1.6.13 (2009-02-03)
  • Support Maretron Label Protocol #2

 

1.6.12 (2008-08-22)
  • Fixed problem preventing custom calibration with Type 2 gauge from working

 

1.6.11 (2008-03-18)
  • Fixed error in CAN filter implementation resulting in non-responsiveness

 

1.6.10 (2008-03-14)
  • Implemented handling for Type 2 (Faria current-controlled) gauges

 

1.6.9 (2008-03-10)
  • Changed so address claims from other addresses are filtered out on receive

 

1.6.6 (2007-10-11)
  • Added back initial programming of EEPROM for mfg. (removed in 1.6.5)

 

1.6.5 (2007-09-28)
  • Corrected issue in CAN driver that caused TLA100 not to respond to product selection sometimes.

 

1.6.4 (2007-25-04)
  • Miscellaneous Improvements

 

1.6.3 (2006-06-29)
  • Initial Public Release