- Products
- Suggested Systems
Suggested Systems
- ACM100 - Alternating Current Monitor
- DCM100 - Direct Current Monitor
- FFM100 - Fluid Flow Monitor
- FPM100 - Fluid Pressure Monitor
- GPS200 - Antenna/Receiver
- J2K100 - J1939 to NMEA 2000 Gateway
- NBE100 - Network Bus Extender
- RAA100 - Rudder Angle Adapter
- SSC300 - Solid State Compass
- SMS100 - Text Messaging
- Support
Support & Downloads
Need help?
- Company

OctoPlex® System Interface Unit Monitor
The System Interface Unit Monitor (SIU) allows the user to interface with up to 34 digital signals (DC discrete inputs) to the OctoPlex® system for status and monitoring purposes. The SIU can be configured to perform Discrete I/O Functions, in conjunction with the AC and DC Distribution units.
Power Input | 10 VDC – 32 VDC |
Power Consumption | 100 mA Max (@ 28 VDC) |
DC Signal Input | Ground; 12 VDC; 24 VDC for each input |
CAN Bus Voltage | +15 VDC (± 0.5) |
Load Equivalence Number | 1 |
Dimensions | 5.89” X 4.74” X 2.95” |
CAN Bus Connectors | Two (2) Micro-C Male |
Operating Temperature | -40°C to +70°C |
Weight | 1.6 lbs (0.73 kg) nominal |
NMEA 2000 | Category B |
Lloyd’s Register | Lloyd’s Type Approved, Test Specification #1, Env 2 |
CE | IEC 60533 Electrical and Electronic Installations in Ships |