You display the SSC200 rate of turn on a DSM150, DSM200, or DSM250 in the following way: Enter menu mode, scroll to "Favorite Screen Setup..." and press Scroll to the favorite screen where you would like to view rate of turn and press Scroll to ... Read More
DSM250 (Discontinued)
The SSC200 compass is aligned with the vessel by pointing the arrow shown on the top of the compass towards the bow. There are alternative mounting options, which can be found the users manual. Once you have performed magnetic deviation calibration... Read More
You display the SSC200 magnetic heading information on a DSM150, DSM200, or DSM250 in the following way: Enter menu mode, scroll to "Favorite Screen Setup..." and press Scroll to the favorite screen where you would like to view the magnetic heading... Read More
The SSC200 compass outputs heading information in magnetic format, so you just need to properly configure the DSM150, DSM200, or DSM250 to display heading in magnetic. To view magnetic heading on the DSM150, DSM200, or DSM250, do the following: Enter... Read More
The TLA100 works with resistive tank senders (i.e., the resistance changes with tank level). In the U.S., the standard for resistive senders is 240 to 30 ohms where 240 ohms represents empty and 30 ohms represents full. The European standard for... Read More
You reset the TLA100 to transmit the factory default messages using Maretron's DSM250 display in the following way: Enter menu mode, scroll to "Configuration:" and press Scroll to "Device Configuration:" and press Scroll to the row containing the... Read More
Yes, it is possible to turn on and off the TLA100 transmitted messages (or PGNs) using Maretron's DSM150, DSM200, or DSM250 display: On the display, enter menu mode, scroll to "Configuration:" and press Scroll to "Device Configuration:" and press ... Read More
Yes, it is possible to program the TLA100 to accept non-standard resistive sensors or odd shaped tanks using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way: Enter... Read More
Yes, it is possible to set the TLA100 to accept American standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way: Enter menu mode, scroll to ... Read More
Yes, it is possible to set the TLA100 to accept European standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way: Enter menu mode, scroll to ... Read More