Maretron's DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Invert Installation:", which is used to describe the orientation of the compass relative to the vessel. For example, the compass can be mounted upside down on... Read More
DSM250 (Discontinued)
Maretron'sDSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Installation Offset Calibration...", which is used to electronically align the compass with the vessel. Although there is an arrow on the compass label, it is... Read More
Maretron's DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Magnetic Deviation Status...", which is used to display information about the deviation table that was stored within the compass when the compass was last... Read More
Maretron's DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Magnetic Deviation Calibration...", which is used to calibrate the compass to account for sources of magnetic deviation on the vessel. Read More
Maretron's DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Variation Source:", which is used to tell the compass from where it should receive the magnetic variation for subsequent transmission of the heading (HDT)... Read More
The SSC200 compass outputs heading information in magnetic form and before N2KView can display true heading, the variation must be known. One source of variation is the Maretron GPS antenna/receiver (GPS200). If an SSC200 and GPS200 are connected... Read More
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Reset Factory Defaults", which is used to return the TLA100 to its factory settings. Resetting the TLA100 resets the tank type back to "Fuel", resets the tank... Read More
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "NMEA 2000 PGN Enable/Disable:", which is used to turn on and off specific messages that are transmitted by the TLA100. Read More
The TLA100 default calibration mode is set to accept the American standard resistance values of 240 to 30 ohms (240 ohms representing empty and 30 ohms representing full). This can be changed using Maretron's DSM150, DSM200, or DSM250 display to... Read More
Maretron's DSM150, DSM200 and DSM250 displays have a TLA100 configuration setting called "Tank Levels Calibration:", which is used to program the type of sensor (American or European standard) that is connected to the TLA100. This setting can also be... Read More