The TLA100 default calibration mode is set to accept the American standard resistance values of 240 to 30 ohms (240 ohms representing empty and 30 ohms representing full). This can be changed using Maretron's DSM150, DSM200, or DSM250 display to... Read More
DSM410
Maretron's DSM150, DSM200 and DSM250 displays have a TLA100 configuration setting called "Tank Levels Calibration:", which is used to program the type of sensor (American or European standard) that is connected to the TLA100. This setting can also be... Read More
If the TLA100's operating mode is set to "NMEA 2000 & Analog Gauge", then it is important to configure the TLA100 with the gauge's resistances in order for the TLA100 to operate correctly. Please refer to the TLA100 Users Manual for a detailed... Read More
The TLA100 can operate in one of two ways: without an analog gauge which is referred to as the "NMEA 2000" mode with an analog gauge which is referred to as the "NMEA 2000 & Analog Gauge" mode The default mode of operation is without an analog... Read More
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Capacity", which is used to set the amount of fluid that the tank can hold. Subsequent transmissions from the TLA100 can then identify how much fluid the... Read More
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Number", which is used to set the tank number so subsequent transmissions from the TLA100 can identify which tank of a particular fluid is being reported ... Read More
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Type", which is used to set the type of fluid so subsequent transmissions from the TLA100 can identify the fluid or tank type. Read More
Maretron's DSM150, DSM200, and DSM250 displays have a WSO100 configuration setting called "Reset Factory Defaults", which is used to return the WSO100 to its factory settings. Resetting the WSO100 clears the installation offset, resets the wind... Read More
Maretron's DSM150, DSM200 and DSM250 displays have a WSO100 configuration setting called "Installation Offset Calibration...", which is used to electronically align the WSO100 with the vessel. Although the WSO100 can be mechanically aligned with the... Read More
In order to display true wind referenced to water speed, you will need a WSO100, a DST110, and a display capable of computing true wind referenced to water speed. The WSO100 measures the apparent wind while the DST110 provides Speed Through Water ... Read More