The resistive tank sensor should produce a resistance value of 33 ohms (American standard) or 180 ohms (European standard) when the tank is full. One possible reason that the tank doesn't register full might be that the sensor doesn't produce the... Read More
TLA100
You connect the TLA100 operating in the NMEA 2000 & Analog Gauge mode to the gauge in the following way: connect the black wire to the gauge ground terminal connect the green wire to the gauge sensor terminal connect the red wire to the gauge... Read More
You connect the TLA100 operating in the NMEA 2000 mode (i.e., without analog gauge) to a resistive sensor in the following way: connect the black wire to the sensor ground terminal connect the white wire to the sensor positive terminal. Read More
To find manufacturers who provide resistive tank senders compatible with the TLA100, search the internet for these terms: fuel and sender, or try these web sites: http://www.wemausa.com http://www.moellermarine.com/aftermarket/fuel_systems... Read More
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Reset Factory Defaults", which is used to return the TLA100 to its factory settings. Resetting the TLA100 resets the tank type back to "Fuel", resets the tank... Read More
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "NMEA 2000 PGN Enable/Disable:", which is used to turn on and off specific messages that are transmitted by the TLA100. Read More
The TLA100 default calibration mode is set to accept the American standard resistance values of 240 to 30 ohms (240 ohms representing empty and 30 ohms representing full). This can be changed using Maretron's DSM150, DSM200, or DSM250 display to... Read More
If the TLA100's operating mode is set to "NMEA 2000 & Analog Gauge", then it is important to configure the TLA100 with the gauge's resistances in order for the TLA100 to operate correctly. Please refer to the TLA100 Users Manual for a detailed... Read More
The TLA100 can operate in one of two ways: without an analog gauge which is referred to as the "NMEA 2000" mode with an analog gauge which is referred to as the "NMEA 2000 & Analog Gauge" mode The default mode of operation is without an analog... Read More
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Capacity", which is used to set the amount of fluid that the tank can hold. Subsequent transmissions from the TLA100 can then identify how much fluid the... Read More