Can I use the SIM100 to tell whether a bulb is burnt out?

Yes, you can use the SIM100 together with a CR Magnetics current sensing relay to indicate that a bulb is burnt out. There are many different available configurations of the current sensing relay, but part numbers that have been tested with the... Read More

Testing a 4-20mA Transducer

Testing a 4-20mA Transducer both Maretron and 3rd party. Please keep in mind of all safety procedures while performing any troubleshooting.   Testing transducer while still connected to NMEA2000® via Maretron FPM100 or CLM100 Components... Read More

What 3-Phase applications is the ACM100 compatible with?

The ACM100 is designed to measure 3-Phase "WYE" configurations. However, it can be used to measure many parameters of 3-phase Delta configurations in the following manner: Configure the ACM100 for a circuit type of "3-Phase Y (Ph. A, B, C)" Use the... Read More

What is the maximum voltage the DCM100 can sense?

The DCM100 can sense voltages up to 50VDC on terminals 5 and 6.The maximum voltage that can be supplied to power the DCM100 on is 32VDC on terminals 7 and 8. Pin Number Signal Name Connection 1 IA Current Sensor, Red Wire 2 IB ... Read More

How do I display the DC Ripple Voltage on the DSM250 display?

You display the DC Ripple Voltage on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Ripple Voltage and press enter. Scroll to ... Read More

How do I display DC Voltage on the DSM250 display?

You display the DC Voltage on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Voltage and press enter. Scroll to "Data:" and... Read More