What is the supplied cable length of the TMP100 sensors; is it possible to extend the cable?
Estimated Reading Time: 1 MinutesMaretron thermistor probes come with 6’ long wires. Yes, you can extend Maretron TMP100 sensor wires to complete temperature sensing applications throughout a vessel.
In many applications technicians have extended thermistor wires up to 100 feet to measure temperatures in separate compartments throughout a vessel. When choosing to extend a thermistor temperature wire, calculate the resistance the wire will add to the measured resistance. Refer to Maretron article: What temperature probes are compatible with Maretron’s Temperature Monitor (TMP100)?
For TMP100 channels 3-6, Maretron uses a 3KΩ @ 25°C thermistor so you can extend the cable with an understanding that an error is introduced into the system as a function of the additional wire resistance.
The stock length of the cable is 10 feet or 3 meters.
THERMISTOR
Maretron Part: TR3K
The image provided is a standard TR3K sensor with stock wire. The wire is designated as Alpha Wire H1 P/N1172C 2 conductor, 22AWG UL spec.
With supplied thermistor probe, Measurement Range – Thermistor -20°C to 80°C (-4°F to 176°F)
With supplied thermistor probe, Measurement Accuracy – Thermistor ± 2°C (± 3.6°F)
THERMOCOUPLE
Maretron Part: TP-EGT-1
Note: Only two separate thermocouple probes can be used on a single TMP100 device (Channel 1: terminals 1 & 2, Channel 2: terminals 3 & 4).
Thermocouple wires can be extended using K-Type thermocouple wires with junction connections ONLY. Review length options with your local supplier. Figure 1 shows an example of a K-type Thermocouple extension wire with junction connections:
With supplied thermocouple probe, Measure ment Range – +0°C to 700°C (32°F to 1292°F)
With supplied thermocouple probe, Measurement Accuracy – ± 2°C (± 3.6°F)