What firmware changes have taken place on the Maretron DCM100 DC Monitor?

Estimated Reading Time: 1 Minutes

What firmware changes have taken place on the Maretron DCM100 DC Monitor? 
Update your device today using the N2KAnalyzer software tool.

 

DCM100 Firmware Revisions

 

1.1.1.3 (2023-06-27)

  • Fix the watchdog reset in gen load default
  • Correct response for testmode command "cal get"
  • Added support for PGN 127751 (DC Voltage/Current)
  • Added support for PGN 123993 (Heartbeat)
  • Added support for PGN 130060 (Label)

 

1.1.1.2 (2023-05-31) (Not Released)

  • Disable dual measuring current range as it cause issue when the DCM is operating with AC current (I) level at the switching/hysteresis region (DCM100SW-2)

1.0.5.2 (2015-03-06)

  • Changed the default value of Time Remaining Floor from 0% to 50% for Lead-Acid batteries, and from 0% to 5% for NiCad and NiMH batteries
  • Changed supported NMEA 2000 database version to 2.000
  • Corrected a problem where the time remaining was transmitted incorrectly when the calculated time remaining was zero
  • Corrected a problem where the time remaining could be transmitted incorrectly under very specific timing conditions
  • Corrected a problem where battery state of charge could be under calculated during extremely high current drain (could go to zero sooner than expected)

1.0.4 (2009-02-23)

  • Improved support for labeling of the device and its channels to store more pertinent information
  • Made the rate of transmission of periodically transmitted messages programmable. This allows you to speed up or slow down the transmission of messages from the device to meet system needs

1.0.3 (2008-12-11)

  • Added support for labeling of the device and its channels with N2KAnalyzer or DSM250. This enables the user to associate a unique text label with the DCM100 to more easily identify it on the network
  • Added support for battery banks with capacity in excess of 800 AH
  • Corrected an issue where current or voltage displayed values could be out of range under certain conditions

1.0.2 (2008-05-15)

  • Corrected a problem where state of charge in PGN 127506 could read > 100% in certain cases

1.0.1 (2008-04-24)

  • Initial public release

 