Maretron Model Device Description NMEA2000 Operating Voltage Engine/Battery Interface CLM100 P/N: M000070 Current Loop Monitor 9 to 32 Volts SSC200 P/N: M000001, M000021, M000022 NMEA 2000 Solid State Compass HW 1.0 9 to 16 Volts ... Read More
FFM100
The FFM100 is compatible with single phase, single pulse sensors for flow measurements such as water and other non-lubricated fluids.This function allows the user to select specific fluid sensors that may provide a higher accuracy for a desired flow... Read More
Yes, The FFM100 can be used to monitor waterflow, however the FFM100 M-series sensors are not intended to be used for water flow applications. The M-Series fuel flow sensors are compatible with fuel, lubricating oil, hydraulic fluid, or... Read More
The FFM100 has an option to set a K-factor for each sensor channel. For the FFM100, the K-factor represents the number of electrical pulses generated by the sensor per liter of fluid passing through it. In order for the FFM100 to be able to calculate... Read More
The FFM100 can update your existing NMEA2000 network to include engine fuel rate. Several components are needed to offer you calculative information for Fuel management such as distance to empty, time to empty, and fuel consumption, to name a few.... Read More
A #4 Nylon Double-Crimp Insulated Ring Terminal(P/N:WT-651045) is the ideal choice when connecting sensor wire to any of Maretron's multi channel devices. The following link provides a great color selection to choose from: http://www.wiringproducts... Read More
***The Maretron M-series sensors do not have a specific torque specification. Refer to each sensors installation instructions for details regarding the integration of each flow sensor. *** Please note the following excerpts below ... Read More