What firmware changes have taken place on the Maretron FPM100?


What firmware changes have taken place on the Maretron FPM100 pressure monitor?

Update your device using the N2KAnalyzer tool.
 

FPM100 Firmware Versions

 

1.1.2.1 (2018-04-27)

- In tank mode, re-enable operation range checking at 4mA (20mA report 100%).

 

1.1.1.2 (2018-04-06)

- Change maximum operating range while operating in pressure mode to 1mA - 24mA (3681). FPM100 will report actual pressure between 4mA – 20 mA. Report minimum pressure between 1mA – 4mA. Report maximum pressure between 20mA – 24mA. Report Out-Of-Range below 1mA or above 24mA 
- Always report data between 0-100% while operating in tank mode without sensor error detection (3681). FPM100 will report actual level between 4mA – 20 mA. Report 0% below 4mA. Report 100% above 20mA.

 

1.0.2.2 (2014-10-31)

- Added support for real-time display of current readings during calibration

 

1.0.1 (2011-11-03)

- Initial Release

 