The DCM100 can sense voltages up to 50VDC on terminals 5 and 6.
The maximum voltage that can be supplied to power the DCM100 on is 32VDC on terminals 7 and 8.
|
Pin Number |
Signal Name |
Connection |
|
1 |
IA |
Current Sensor, Red Wire |
|
2 |
IB |
Current Sensor, Green Wire |
|
3 |
IC |
Current Sensor, Black Wire |
|
4 |
ID |
Current Sensor, White Wire |
|
5 |
VSENS+ |
Battery, + Terminal |
|
6 |
VSENS- |
Battery, - Terminal |
|
7 |
VPWR- |
Vessel Ground |
|
8 |
VPWR+ |
9-16 V Power |
|
9 |
No Connect |
|
|
10 |
No Connect |
|
|
11 |
TA |
Temperature Sender, Red Wire |
|
12 |
TB |
Temperature Sender, Black Wire |
Article ID: 487
Created: October 15, 2010
Last Updated: July 28, 2015
Author: Mark Oslund [[email protected]]