1. Connect
the MD-6517-N power terminals to a 7-16VDC supply that is independent of the
NMEA 2000 network power supply as shown in Figure 1 below. Powering the unit
separately from the NMEA 2000 network allows the detector to work even when the
NMEA 2000 network is powered off.
2. Connect
the COM and T/NO terminals to a free switch channel. The example in Figure 1
shows the detector connected to switch channel 1, terminals “SW1A” and “SW1B”.
3. Use
a Maretron DSM250 display (firmware 1.3.5 or higher), the DSM250 Viewing
function of Maretron N2KAnalyzer software, or other Maretron display product
capable of configuring the SIM100 to set the switch channel mode (indicated as
“Channel #x Mode” on the DSM250) for the appropriate channel to the “End of
Line Resistor” setting. For this example, you would set “Channel #1 Mode” to
“End of Line Resistor”.
4. Supply
power to the NMEA 2000 network and to the MD-6517-N and verify that the switch
channel indicates an “off” (normal) state using Maretron N2KView software,
N2KAnalyzer, or other product capable of displaying switch indicator state.
5. Perform
a walktest on the MD-6517-N and verify that the switch channel indicates an “on”
(alarm) state during the test.
6. Disconnect
one of the alarm wires from the SIM100 and verify that the switch channel
indicates an “error” state.
7. Reconnect
the alarm wires to the SIM100 and verify that the switch channel indicates an
“off” (normal) state.
|
WARNING: The MD-6517-N is shipped with a
8KΩ end-of-line resistor installed between the COM terminal and the T/NO
terminal. Do not remove the resistor, as it is required for proper operation. |