  1. Using N2KAnalyzer, how do I recover a Maretron device? Occasionally, a device can be in "boot mode" (represented in N2KAnalyzer by an orange highlight of the device's entry in the device list). This can happen due to a software update which fails due to network problems.A Maretron device that is not... Read More
  2. How do I perform J2K100 quick setup using the N2KAnalyzer program? Refer to this article for help on setting up your first J2K100 especially when connected to the following engine manufacturers J1939 networks:Caterpillar, John Deere, Cummins, Steyr, ECU Delphi Mefi 4-6, Crusader, MAN, Detroit Diesel, Volvo-Penta (EV... Read More
  3. What software changes have taken place with N2KAnalyzer? What changes have taken place with the N2KAnalyzer?Current Version Available:  N2KAnalyzer 2.4.16 Updates for FFM100, DSM150, DSM250, features for N2K diagnostics, and much more.   **USERS RUNNING N2KANALYZER VERSION 2.1.14, YOU WILL NEED TO MANUALLY... Read More
  4. What is an N2KAnalyzer "boat file"? N2KAnalyzer allows you to save information about a particular network for a given boat or vessel into what is called a "boat file". You can read the boat file back into N2KAnalyzer at a later time or you can even send the boat file to Maretron's... Read More
  5. How do I read a previously saved boat file back into N2KAnalyzer?  You read a previously saved boat file back into N2KAnalyzer by selecting the "File" menu and clicking on the "Open..." menu item. You can only read a boat file back into N2KAnalyzer if N2KAnalyzer is disconnected from an NMEA 2000 network (connectio... Read More
  6. How do I save and load a configuration file for a TLM100, TLM150, or TLM200 using N2KAnalyzer? N2KAnalyzer has a feature that allows for the user to load a saved configuration table onto a TLM100,TLM150, or TLM200 on the NMEA 2000 network. To load a configuration file, use the following process:Start the N2KAnalyzer program.Select a gateway to... Read More
  7. Can Maretron’s DSM150 or DSM250 display or N2KAnalyzer configure certain Airmar transducers? Yes, Maretron's multi-function color displays (DSM150 and DSM250) or Maretron's N2KAnalyzer configuration tool (used in conjunction with the USB100 or IPG100 gateway) can be used to configure certain Airmar transducers. Please see the attac... Read More
  8. Does N2KAnalyzer offer a software tool to perform fluid level calibrations for all of Maretron’s tank monitoring products? Yes, N2Kanalyzer offers two types of tank calibrations: Manual Table and Step Fill. Both configuration features can be used to calibrate the correct tank volume for your Maretron tank monitoring product.Used in in conjunction with any of Maretron... Read More
  9. Does Maretron offer a Quick Setup guide for the SIM100 using N2KAnalyzer? Maretron's Switch Indicator Module monitors dry contacts. Once you have selected the dry contact device, connect the two leads from the device to one of six SIM100 channels.Each channel has two terminals; for example, Channel #0 uses terminals 1... Read More
  10. How do I perform a TLM100 quick setup for a square tank using the N2KAnalyzer program? Quick setup guide for a TLM100. The following article was written assuming you(reader) are familiar with Maretron configuration tools and products. This article is intended for advanced users and NMEA certified Technicians who require quick reference... Read More
Displaying 1 to 10 out of 58 records First Page Previous Page Page of 6 Next Page Last Page