  1. What firmware changes have taken place on the Maretron DSM150? You can update the device with Maretron's N2KAnalyzer  software tool. 1.7.5.3(2018-01-24):Correctly display invalid data in LAT/LON screen (4405)Correctly display PGN 129029 data in LAT/LON screen (4418)Fixed crashing issue in control mode while... Read More
  2. Helpful information regarding Smoke/Heat Detector - SH-449CSTE Installation notes:Smoke detectors are shipped with a plastic dust cover for use in areas where construction is on-going. Smoke detectors will not workwith the dust cover in place. Remove the dust cover when installation is completed, prior to testin... Read More
  3. I see an option for FFM100 configuration called K-factor; what does this mean? The FFM100 has an option to set a K-factor for each sensor channel. For the FFM100, the K-factor represents the number of electrical pulses generated by the sensor per liter of fluid passing through it. In order for the FFM100 to be able to calculate... Read More
  4. What is the torque specification for Maretron’s M-series fluid flow sensors? ***The Maretron M-series sensors do not have a specific torque specification. Refer to each sensors installation instructions for details regarding the integration of each flow sensor. ***Please note the following excerpts below (6 & 7) found wit... Read More
  5. I have installed the TLM100 and see incorrect tank levels; what does this mean?  The TLM100 uses an ultrasonic signal to determine a distance measurement from sensor to level.The tank application must be compatible with the TLMXXX measurement technology. If you have already installed a TLMXXX and received unexpected results, the... Read More
  6. What firmware changes have taken place on the Maretron SSC200? What firmware changes have taken place on the Maretron SSC200 Compass? Update your device today using the N2KAnalyzer software tool.SSC200 Firmware Versions5.0.4.1(2013-07)Correct Gyro Offset Table Issue (2463)Increase the acceptable error range of G... Read More
  7. I see that the FFM100 has a configuration called "Sensor:1-Phase"; what is this option used for? The FFM100 is compatible with single phase, single pulse sensors for flow measurements such as water and other non-lubricated fluids.This function allows the user to select specific fluid sensors that may provide a higher accuracy for a desired flow ... Read More
  8. What firmware changes have taken place on the Maretron FPM100?    1.1.2.1 (2018-4-27) In tank mode, re-enable operation range checking at 4mA (20mA report 100%).1.1.1.2(2018-4-6)Change maximum operating range while operating in pressure mode to 1mA - 24mA (3681). FPM100 will report actual pressure between 4mA – ... Read More
  9. Does Maretron offer quick setup instructions for the FFM100 in a single diesel engine application? The prerequisite for using this guide requires the use of a Windows PC and Maretron's N2KAnalyzer program installed. The hardware required for Maretron device configuration is the USB100 or IPG100 Gateway connected to a powered N2K network with ... Read More
  10. What firmware changes have taken place on the Maretron IPG100 ? You can update the IPG100 using the N2KAnalyzer software tool.IPG100 4.1.3.3(2018-01-24):Added support for the latest NMEA2000 PGN (4431)Added support for the NMEA 2000 Heartbeat Message (PGN 126993) (4436)Added ability to notify N2KView when IPG100'... Read More