What is the default calibration setting for the RAA100?
The RAA100 default calibration mode is set to accept the American standard resistance values of 240 to 30 ohms (240 ohms representing 60 degrees to port and 30 ohms representing 60 degrees to starboard). This can be changed using Maretron's DSM1... Read More
Why doesn’t my tank display doesn’t read full when the tank is full?
The resistive tank sensor should produce a resistance value of 33 ohms (American standard) or 180 ohms (European standard) when the tank is full. One possible reason that the tank doesn't register full might be that the sensor doesn't produ... Read More
Why doesn’t my tank display doesn’t read empty when the tank is empty?
The resistive tank sensor should produce a resistance value of 240 ohms (American standard) or 10 ohms (European standard) when the tank is empty. One possible reason that the tank doesn't register empty might be that the sensor doesn't pro... Read More
How do I calibrate the SSC200 to account for magnetic deviation?
The SSC200 can be calibrated to account for magnetic deviation in several ways; please refer to the SSC200 User's Manual for instructions. It is always best to calibrate the rate of turn gyro before you perform magnetic deviation calibration on ... Read More