  1. What is the default calibration setting for the RAA100? The RAA100 default calibration mode is set to accept the American standard resistance values of 240 to 30 ohms (240 ohms representing 60 degrees to port and 30 ohms representing 60 degrees to starboard). This can be changed using Maretron's DSM1... Read More
  2. Can I custom calibrate the RAA100 for non-standard resistance sensors or can I do custom calibration for hard over points other than 60 degrees? Yes, it is possible to calibrate the RAA100 to accept non-standard resistive sensors or to set custom hard over angles using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the followin... Read More
  3. Does N2KAnalyzer offer a software tool to perform quick fluid level calibrations for all of Maretron’s tank monitoring products? Yes, N2Kanalyzer offers two types of tank calibrations: Manual Table and Step Fill. Both configuration features can be used to calibrate the correct tank volume for your Maretron tank monitoring product.Used in in conjunction with any of Maretron... Read More
  4. Can I set the TLA100 to accept the European standard for resistance values (i.e. 10 to 180 ohms) using Maretron’s DSM150, DSM200, or DSM250 display? Yes, it is possible to set the TLA100 to accept European standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, sc... Read More
  5. Can I set the TLA100 to accept the American standard for resistance values (i.e. 240 to 33 ohms) using Maretron’s DSM150, DSM200, or DSM250 display? Yes, it is possible to set the TLA100 to accept American standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, sc... Read More
  6. I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Reset Factory Defaults"; what is this? Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Reset Factory Defaults", which is used to return the TLA100 to its factory settings. Resetting the TLA100 resets the tank type back to "Fuel", resets the ... Read More
  7. Why doesn’t my tank display doesn’t read full when the tank is full? The resistive tank sensor should produce a resistance value of 33 ohms (American standard) or 180 ohms (European standard) when the tank is full. One possible reason that the tank doesn't register full might be that the sensor doesn't produ... Read More
  8. Why doesn’t my tank display doesn’t read empty when the tank is empty? The resistive tank sensor should produce a resistance value of 240 ohms (American standard) or 10 ohms (European standard) when the tank is empty. One possible reason that the tank doesn't register empty might be that the sensor doesn't pro... Read More
  9. Can I use the TLA100 if I don’t have a rectangular tank? Yes, the TLA100 can be custom configured with up to 16 calibration points to accommodate irregularly shaped or odd shaped tanks.... Read More
  10. How do I calibrate the SSC200 to account for magnetic deviation? The SSC200 can be calibrated to account for magnetic deviation in several ways; please refer to the SSC200 User's Manual for instructions. It is always best to calibrate the rate of turn gyro before you perform magnetic deviation calibration on ... Read More
Displaying 11 to 20 out of 59 records First Page Previous Page Page of 6 Next Page Last Page