Knowledge Base

Articles: Search Results

  1. What are the dimensions of the DCM100 current transducers? The DCM100 is packaged with a Hall Effect sensor (P/N: LEMHTA200-S) which is rated to measure currents up to 200 Amperes.If your application requires measurements exceeding 200 Amperes,  Maretron offers additional sensors:400 Amperes measurement. Use... Read More
  2. What are the specifications for the Current Transformer (CT) that comes with the Maretron AC Monitor (ACM100)?  The ACM100's current transformer specifications are as follows: Part Number: M000630Current Range: 100 AmpsOutput Ratio to Input: 1000:1 (100maAC Max)Frequency Range: 45-60HZDielectric Withstand: 1000VAC (RMS)Insulation resistance Class: .5KVFu... Read More
  3. What happens when I use the TLM100/150 without a focus tube? A focus tube is recommended for tank applications that experience a drastic level change when the vessel is underway.The TLM100 transmits an ultrasonic pulse that allows the device to calculate the distance from the sensor to the fluid surface (simil... Read More
Displaying 11 to 13 out of 13 records First Page Previous Page Page of 2 Next Page Last Page