Knowledge Base

Articles: Search Results

  1. How do I display the J2K100 generator average line-line AC voltage on Maretron’s DSM150 or DSM250 display? You display the J2K100 generator average line-line AC voltage on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the v... Read More
  2. How do I display the J2K100 generator average line-neutral AC RMS voltage on Maretron’s DSM150 or DSM250 display? You display the J2K100 generator average line-neutral AC voltage on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view th... Read More
  3. How do I display DC Voltage on the DSM250 display? You display the DC Voltage on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Voltage and press enter. Scroll to "Data:" and pre... Read More
  4. How do I display the DC Ripple Voltage on the DSM250 display? You display the DC Ripple Voltage on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Ripple Voltage and press enter. Scroll to "... Read More
  5. What are the voltage specifications for each Maretron device? Maretron ModelDevice DescriptionNMEA2000 Operating VoltageEngine/Battery InterfaceCLM100 P/N: M000070 Current Loop Monitor9 to 32 Volts SSC200 P/N: M000001, M000021, M000022NMEA 2000 Solid State Compass HW 1.09 to 16 Volts SSC300 P/N: M000051NMEA ... Read More
  6. What is the maximum voltage the DCM100 can sense? The DCM100 can sense voltages up to 50VDC on terminals 5 and 6.The maximum voltage that can be supplied to power the DCM100 on is 32VDC on terminals 7 and 8.Pin NumberSignal NameConnection1IACurrent Sensor, Red Wire2IBCurrent Sensor, Green Wire3ICCur... Read More
  7. Can I use the SIM100 to tell whether a bulb is burnt out? Yes, you can use the SIM100 together with a CR Magnetics current sensing relay to indicate that a bulb is burnt out. There are many different available configurations of the current sensing relay, but part numbers that have been tested with the SIM10... Read More
  8. What 3-Phase applications is the ACM100 compatible with? The ACM100 is designed to measure 3-Phase "WYE" configurations. However, it can be used to measure many parameters of 3-phase Delta configurations in the following manner:Configure the ACM100 for a circuit type of "3-Phase Y (Ph. A, B, C)"Use the fol... Read More
  9. How do I check the health of my NMEA 2000 cabling before powering my network? Maretron recommends using an N2KMeter to properly check NMEA 2000 network health when powered and devices are operational. The N2KMeter can also provide a real-time detection of powered device communication issues such as excessive error frames, bit ... Read More
  10. Does Maretron offer quick setup instructions for the FFM100 in a dual diesel engine application? The prerequisite for using this guide requires the use of a Windows PC and Maretron's N2KAnalyzer program installed. The hardware required for Maretron device configuration is the USB100 or IPG100 Gateway connected to a powered N2K network with ... Read More
Displaying 1 to 10 out of 37 records First Page Previous Page Page of 4 Next Page Last Page