  1. How do I calibrate the SSC200 roll to read zero using Maretron’s DSM150, DSM200, or DSM250 display? You can calibrate the SSC200 roll to read zero when the vessel is sitting flat in the water using a DSM150, DSM200, or DSM250 display. To zero the roll:Enter menu mode, scroll to "Configuration..." and press < Enter >Scroll to "Device Configuration..... Read More
  2. Why does the SSC200 roll angle not read zero when the vessel is flat in the water? You can calibrate the SSC200 roll angle to read zero when the vessel is sitting flat in the water using a DSM150, DSM200, or DSM250 display. To zero the roll:Enter menu mode, scroll to "Configuration..." and press < Enter >Scroll to "Device Configura... Read More
  3. How do I display the SSC200 roll angle on Maretron’s DSM150, DSM200, or DSM250 display? You display the SSC200 roll angle on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view roll and press < Enter >Scroll t... Read More
  4. How do I connect the Dometic Q-logic controller to the J2K100 for N2KView control? First, you will need to purchase or connect the Q-logic J1939 board or confirm you have one already working on board your vessel. Figure 1 illustrates what the Q-logic J1939 interface should look like.Once you can confirm the J1939 interface is conne... Read More
  5. AXIS Camera Setup for N2KView  Within this article outlines a basic setup guideline for integrating your AXIS camera or AXIS encoder that is connected to the same LAN as your device running N2KView (TSM, MBB, and/or computer). Access your AXIS camera via your browser using either... Read More
  6. What firmware changes have taken place on the Maretron DSM570? DSM570 Firmware VersionsWhat firmware changes have taken place on the Maretron DSM570 display?Update your device using the N2KAnalyzer software tool. 1.8.6.3 (2022-03-16)Fix rolling toad trail issue on VGA resolution displayCorrect Demo icon position... Read More
  7. What firmware changes have taken place on the Maretron DSM410? What firmware changes have taken place on the Maretron DSM410 display?Update your device using the N2KAnalyzer software tool. DSM410 Firmware Versions 1.8.6.3 (2022-03-16)Fix rolling toad trail issue on VGA resolution displayCorrect Demo icon positio... Read More
  8. Testing a 4-20mA Transducer Testing a 4-20mA Transducer both Maretron and 3rd party.Please keep in mind of all safety procedures while performing any troubleshooting. Testing transducer while still connected to NMEA2000® via Maretron FPM100 or CLM100Components requiredPC runnin... Read More
  9. What are the latest changes to Maretron’s N2KView? Maretron announces the release of version 6.4 of the N2KView® V3 software.The Computer (PC & MAC) version of N2KView is available via the following link https://www.maretron.com/products/N2KView.php?tab=9The TSM800C, TSM810C, TSM1330C and MBB300C... Read More
  10. What firmware changes have taken place on the Maretron SSC300? What firmware changes have taken place on the SSC300? 1.0.6.1(2016-8)Corrected a problem where "SSC300" was not recognized in configuration commands sent over the NMEA 0183 interface (3707)1.0.5(2016-4)Manufacturing improvement1.0.4.1(2015-10)Correct... Read More