What messages (or PGNs) does the DCM100 transmit?

The DCM100 transmits the following messages: 127506 DC Detailed Status: (DC Instance, DC Type, State of Charge, State of Health, Time Remaining, and Ripple Voltage. 127508 Battery Status: (Battery Instance, Battery Voltage, Battery Current, Battery Case Temperature) 127513 Battery Configuration Status: (Battery Instance, Battery Type, Supports Equalization, Nominal Voltage, Battery Chemistry, Battery Capacity, Battery Temperature Coefficient, Peukert Exponent, and Charge Efficiency Factor.