What type of information can be viewed on Maretron’s display products, and what products are required to generate the data to be displayed?
Viewed 25729 times since Tue, Oct 25, 2011
The Maretron Capability Matrix helps highlight the system features available for display when designing a system within N2KBuilder. To generate a system capability Matrix within N2KBuilder simply click on Tools, "Create Maretron Capability Matrix". ... Read More
Is it possible to wire a manual override switch around the DCR100?
Viewed 18494 times since Tue, Apr 26, 2011
Yes, you can use a manual switch to override the DCR100. Please see the attached diagrams which shows three different circuit configurations. The first circuit diagram shows how the DCR100 is wired into a circuit without any type of manual override. ... Read More
What are the voltage specifications for each Maretron device?
Viewed 8439 times since Thu, Dec 22, 2011
Maretron ModelDevice DescriptionNMEA2000 Operating VoltageEngine/Battery InterfaceCLM100 P/N: M000070 Current Loop Monitor9 to 32 Volts SSC200 P/N: M000001, M000021, M000022NMEA 2000 Solid State Compass HW 1.09 to 16 Volts SSC300 P/N: M000051NMEA ... Read More
How do I show simple bilge information on Mareton’s DSM150 or DSM250 displays?
Viewed 6171 times since Sat, Apr 27, 2013
Knowldege base article 578 showed how to do simple bilge monitoring using Maretron's Run Indicator Module (RIM100). This article shows how the monitored information from article 578 can be displayed on Maretron's DSM150 and DSM250 displays.... Read More
Using N2KAnalyzer, how do I recover a Maretron device?
Viewed 5418 times since Thu, Dec 22, 2011
Occasionally, a device can be in "boot mode" (represented in N2KAnalyzer by an orange highlight of the device's entry in the device list). This can happen due to a software update which fails due to network problems.A Maretron device that is not... Read More
What type of solderless connector is ideal for connecting sensor wire to Maretron multi-channel products?
Viewed 4790 times since Wed, Oct 19, 2011
A #4 Nylon Double-Crimp Insulated Ring Terminal(P/N:WT-651045) is the ideal choice when connecting sensor wire to any of Maretron's multi channel devices.The following link provides a great color selection to choose from: http://www.wiringprodu... Read More
What firmware changes have taken place on the Maretron DCR100?
Viewed 4031 times since Fri, Jul 19, 2013
What firmware changes have taken place on the Maretron DCR100 Relay Module?You can update your device using the N2KAnalyzer software tool. DCR100 Firmware Versions 1.1.2.3 (2013-07-19)Removed support for the deprecated 127502 Switch Bank Control p... Read More
The DCR100 will not allow me to switch on/off a relay channel. Why?
Viewed 3796 times since Thu, Sep 13, 2012
The DCR100 has a DC current calibration option. If you have connected a DC load to a channel of the DCR100 and have not performed the "Current Sensor Zero Offset Calibration", this may affect the command of this channel especially if the DCR100 detec... Read More
Can I use the DCR100 to switch AC loads?
Viewed 3786 times since Mon, May 21, 2012
You can not use the DCR100 to directly switch AC loads, but you can use the DCR100 with an external relay to turn On and Off AC loads.- A Solid State Relay (SSR) can be used to switch an AC load as shown in the illustration below. Read More
Can I turn On and Off loads connected to the DCR100 using the DSM150 or DSM250?
Viewed 3568 times since Thu, May 5, 2011
Yes, you can turn On and Off loads connected to the DCR100 using the DSM150 or DSM250. To do so, you should understand a few things about the DSM150 or DSM250 and its favorite screens. First, you need to understand how to setup a favorite screen with... Read More
What is a DCR100?
Viewed 3528 times since Sat, Apr 30, 2011
Maretron's DCR100 contains 6 Direct Current (DC) relays, each capable of switching up to 10 Amps at 12VDC or 24VDC. The DCR100 connects directly to an NMEA 2000® network, so you can turn on and off the relays from a Maretron DSM150 or DSM250 dis... Read More
I see N2KView offers a component for "Indicator Status"; what products can I use to show Indicator Status?
Viewed 3504 times since Fri, Mar 27, 2015
An Indicator Status component uses the NMEA 2000 message called "Binary Switch Bank Status" to show three condition states:OnOffErrorA RIM100, SIM100, and DCR100 all transmit the necessary message for the N2KView component to work.You can create seve... Read More
Does the DCR100 provide overcurrent circuit protection?
Viewed 3425 times since Thu, Apr 28, 2011
No, the DCR100 does not provide overcurrent circuit protection. The DCR100 contains six Solid State Relays (SSRs), which need to be individually overcurrent protected. The following diagram shows the individual SSRs protected with individual circuit ... Read More
Can I use the DCR100 to detect burnt out lights or burnt out loads?
Viewed 3368 times since Sat, May 7, 2011
Yes, you can use the DCR100 in conjunction with Maretron's display products (e.g., N2KView, DSM150, or DSM250) to detect burnt out loads. You can do this in one of two ways; 1) setup a favorite screen to monitor the DC current for a particular l... Read More
Can I use the DSM150 or DSM250 to configure a DCR100?
Viewed 3350 times since Tue, May 10, 2011
Yes, you can use a DSM150 or DSM250 to configure a DCR100. Please watch the following video to see how it's done. Read More
Do the Solid State Relays (SSRs) within the DCR100 turn off if the NMEA 2000 power is removed from the DCR100?
Viewed 3346 times since Wed, Apr 27, 2011
Yes, the SSRs within the DCR100 turn off if the NMEA 2000 power is removed from the DCR100. By default, once NMEA 2000 power is reapplied to the DCR100, the individual SSRs will return to the state that they were in at the time power was removed. In ... Read More
In addition to switching On and Off DC loads, can I use the DCR100 to monitor current flow to the loads?
Viewed 3344 times since Sat, May 7, 2011
Yes, you can use the DCR100 to monitor DC current flow to loads using one of Maretron's display products (e.g., N2KView, DSM150, or DSM250). Each of the six channels within the DCR100 reports how much current is flowing to the load, which is use... Read More
Can Non-Maretron displays control the DCR100?
Viewed 3189 times since Mon, Jul 13, 2015
Can third party (non-Maretron) controls or displays command the DCR100 to toggle whether in Switch or ALM mode?The DCR100 reports status using the standard NMEA2000 message 127501 that any NMEA2000 display can interpret, but to command the DCR100 to ... Read More
Can I use the DCR100 to turn on my Marine Audio Amplifier ?
Viewed 3088 times since Tue, Jul 19, 2016
Yes, The DCR100 can control your audio amplifier by way of the “Remote” input to the amplifier. For vessels with large audio networks an N2KView user can use this feature to selectively control audio amplifiers by way of a single or multiple DCR100 c... Read More
How do I switch a relay channel on the Maretron DCR100 using a non-Maretron display?
Viewed 2723 times since Thu, Jun 27, 2013
Maretron displays perform switching (on/off) of the solid-state relays in the DCR100 via the NMEA standard method of using an NMEA Command (PGN 126208) of the 127501 Binary Switch Bank Status message. The Switch Bank Indicator field, along with the I... Read More
I see that the DCR100 has a configuration feature called Operating Mode, What does this mean?
Viewed 2321 times since Thu, Mar 23, 2017
DCR100 channels have two possible operating modes: “Normal”, in which the DCR100 channel responds to standard NMEA 2000 switching commands, and “Annunciator”, in which the channel may be connected to a power source for a sounder or a light to be acti... Read More
|