What type of information can be viewed on Maretron’s display products, and what products are required to generate the data to be displayed?
Viewed 25598 times since Tue, Oct 25, 2011
The Maretron Capability Matrix helps highlight the system features available for display when designing a system within N2KBuilder. To generate a system capability Matrix within N2KBuilder simply click on Tools, "Create Maretron Capability Matrix". ...
Read More
What are the voltage specifications for each Maretron device?
Viewed 8314 times since Thu, Dec 22, 2011
Maretron ModelDevice DescriptionNMEA2000 Operating VoltageEngine/Battery InterfaceCLM100 P/N: M000070 Current Loop Monitor9 to 32 Volts SSC200 P/N: M000001, M000021, M000022NMEA 2000 Solid State Compass HW 1.09 to 16 Volts SSC300 P/N: M000051NMEA ...
Read More
Using N2KAnalyzer, how do I recover a Maretron device?
Viewed 5311 times since Thu, Dec 22, 2011
Occasionally, a device can be in "boot mode" (represented in N2KAnalyzer by an orange highlight of the device's entry in the device list). This can happen due to a software update which fails due to network problems.A Maretron device that is not...
Read More
What is the procedure for testing the ALM100 Annunciator?
Viewed 4910 times since Thu, Jan 8, 2015
The procedure for testing an ALM100 can be performed using the following Maretron User Interface products:DSM150/DSM250:Go to Main Menu-->Scroll to Configuration-->Select "Device Configuration"-->Select the ALM00 you wish to test-->Scroll to "Test An...
Read More
What firmware changes have taken place on the Maretron ALM100 Alarm Module?
Viewed 3399 times since Thu, Jan 19, 2012
What firmware changes have taken place on the Maretron ALM100 Alarm Module? Update your device using the N2KAnalyzer software tool paired with a Maretron gateway. ALM100 Firmware Versions 1.0.6 (2010-08-13)Updated supported NMEA 2000 database versi...
Read More
Which Martron products work with the ALM100?
Viewed 2406 times since Wed, Jun 22, 2016
The ALM100 can be commanded to annunciate by way of Maretron Displays(excluding legacy DSM200) or PC software N2KView(alerts enabled) only. Third-Party devices, Chart-plotters, and MFDs are not compatible to with the ALM100.
Read More
I see that the ALM100 has a fixed tone output of 105 Decibels. With the dampener accesory closed what is the decibel rating?
Viewed 1979 times since Thu, Jan 8, 2015
The ALM100 has a low decibel of 97dB when the sound dampener is completely closed. The dampener can be adjusted to support a tone range of 97dB to 105dB.