What type of information can be viewed on Maretron’s display products, and what products are required to generate the data to be displayed?
Viewed 25727 times since Tue, Oct 25, 2011
The Maretron Capability Matrix helps highlight the system features available for display when designing a system within N2KBuilder. To generate a system capability Matrix within N2KBuilder simply click on Tools, "Create Maretron Capability Matrix". ... Read More
Can Maretron devices be displayed on a Raymarine Seatalk NG network?
Viewed 10763 times since Wed, Feb 25, 2015
Yes, many of Maretron device's data can be displayed on Raymarine Chart-plotters With Seatalk and Seatalk ng functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the Maretron product's datashee... Read More
What are the voltage specifications for each Maretron device?
Viewed 8439 times since Thu, Dec 22, 2011
Maretron ModelDevice DescriptionNMEA2000 Operating VoltageEngine/Battery InterfaceCLM100 P/N: M000070 Current Loop Monitor9 to 32 Volts SSC200 P/N: M000001, M000021, M000022NMEA 2000 Solid State Compass HW 1.09 to 16 Volts SSC300 P/N: M000051NMEA ... Read More
Can Maretron’s sensor data be displayed on a Garmin network?
Viewed 8139 times since Mon, Jun 12, 2017
Yes, much of Maretron device's data can be shown on Garmin displays with “NMEA 2000” functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the Maretron product's datasheet specifically, the tran... Read More
Using N2KAnalyzer, how do I recover a Maretron device?
Viewed 5418 times since Thu, Dec 22, 2011
Occasionally, a device can be in "boot mode" (represented in N2KAnalyzer by an orange highlight of the device's entry in the device list). This can happen due to a software update which fails due to network problems.A Maretron device that is not... Read More
What is the SMS100 Status message? Which Maretron components do I need?
Viewed 5138 times since Thu, Jun 6, 2013
The SMS100 Status Message is a text message you can receive from the SMS100 containing key pieces of information regarding your vessel. When the SMS100 is installed, you can text the word "Status" to your SMS100 cellular number and receive a respons... Read More
What type of solderless connector is ideal for connecting sensor wire to Maretron multi-channel products?
Viewed 4790 times since Wed, Oct 19, 2011
A #4 Nylon Double-Crimp Insulated Ring Terminal(P/N:WT-651045) is the ideal choice when connecting sensor wire to any of Maretron's multi channel devices.The following link provides a great color selection to choose from: http://www.wiringprodu... Read More
Can Maretron’s sensor data be displayed on a Furuno CANBUS network?
Viewed 4752 times since Mon, Jun 12, 2017
Yes, much of Maretron device's data can be shown on Furuno displays with “CANBUS” functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the Maretron product's datasheet specifically, the transmi... Read More
What messages (or PGNs) does the DCM100 transmit?
Viewed 3997 times since Fri, Nov 7, 2008
The DCM100 transmits the following messages:
127506 DC Detailed Status: (DC Instance, DC Type, State of Charge, State of Health, Time Remaining, and Ripple Voltage.
127508 Battery Status: (Battery Instance, Battery Voltage, Battery Current, Battery ... Read More
What is a DCM100?
Viewed 3760 times since Fri, Nov 7, 2008
Maretron’s DCM100 is a device which monitors DC power sources or batteries and outputs information about these sources onto the industry standard NMEA 2000® marine data network. Read More
How do I set the DCM100 configuration setting called "Instance:" using Maretron’s DSM250 display?
Viewed 3758 times since Fri, Nov 7, 2008
You set the DSM100 configuration setting called " Instance:" using Maretron's DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and press enter. Scroll to the row conta... Read More
Where would I use a DCM100?
Viewed 3728 times since Fri, Nov 7, 2008
You use the DCM100 if you have a Battery bank or a DC source network connection and you want to display DC bateries or DC electrical information on an NMEA 2000 compatible display. Read More
What information does the DCM100 provide over the NMEA 2000 network?
Viewed 3710 times since Fri, Nov 7, 2008
The DCM100 can provide Voltage, Power, Current, Battery Case Temperature, Time remaining, Ripple Voltage, State of health, and State of charge. Review your NMEA 2000 Displays user manual to verify that above Items can be viewed. Read More
What firmware changes have taken place on the Maretron DCM100 DC Monitor?
Viewed 3585 times since Wed, Jan 18, 2012
What firmware changes have taken place on the Maretron DCM100 DC Monitor? Update your device today using the N2KAnalyzer software tool. DCM100 Firmware Revisions 1.0.5.2 (2015-03-06)- Changed the default value of Time Remaining Floor from 0% to 50% f... Read More
How do I display the DC State of Charge on the DSM250 display?
Viewed 3327 times since Fri, Nov 7, 2008
You display the DC State of Charge on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC State of Charge and press enter. Scroll t... Read More
How do I display DC Voltage on the DSM250 display?
Viewed 3293 times since Fri, Nov 7, 2008
You display the DC Voltage on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Voltage and press enter. Scroll to "Data:" and pre... Read More
Is it possible to turn on or off DCM100 NMEA 2000 transmitted messages (or PGNs)?
Viewed 3282 times since Fri, Nov 7, 2008
Yes, it is possible to turn on and off the DCM100 transmitted messages (or PGNs) using Maretron's DSM250 display. On the display, enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and press enter. Scroll t... Read More
How do I display the DC Time Remaining on the DSM150 or DSM250 display?
Viewed 3200 times since Fri, Nov 7, 2008
You display the DC Time Remaining on the DSM150 or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press Enter. Scroll to the favorite screen where you would like to view the DC Time Remaining and press Enter. S... Read More
How do I display the DC Ripple Voltage on the DSM250 display?
Viewed 3196 times since Fri, Nov 7, 2008
You display the DC Ripple Voltage on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Ripple Voltage and press enter. Scroll to "... Read More
I see that Maretron’s DSM250 displays have a DCM100 configuration setting called "Reset Factory Defaults"; what is this?
Viewed 3196 times since Fri, Nov 7, 2008
Maretron's DSM250 displays have a DCM100 configuration setting called "Reset Factory Defaults", which is used to return the DCM100 to its factory settings. Resetting the DCM100 sets the NMEA 2000 instance back to 0 and returns PGN enable/disable back... Read More
I see that Maretron’s DSM150 and DSM250 displays have a DCM100 configuration setting called "Instance:"; what is this?
Viewed 3140 times since Fri, Nov 7, 2008
Maretron's DSM150 and DSM250 displays have a DCM100 configuration setting called "Instance:", which is used to program the DCM100 to transmit the appropriate NMEA 2000 instance. For example, if the DCM100 is connected to a DC source, then this c... Read More
Does Maretron offer a quick setup guide for the DCM100?
Viewed 3106 times since Tue, Sep 4, 2012
Configuring the DCM100 using the DSM150 or DSM250 display.Perform a current sensor zero offset with the current sensor attached to the DCM100.Step two: Scroll to DC Type and input the DC battery configuration:Configuring the DCM100 using the N2KAnaly... Read More
With regards to the DCM100, where should I connect the ring terminal of temperature sensor (part number TR3K)?
Viewed 3103 times since Mon, Jun 29, 2009
You should connect the ring terminal on the Temperature Sensor to the negative terminal of the DC source being monitored. Read More
I see that Maretron’s DSM150 and DSM250 displays have a DCM100 configuration setting called "NMEA 2000 PGN Enable/Disable..."; what is this?
Viewed 3047 times since Fri, Nov 7, 2008
Maretron's DSM150 and DSM250 displays have a DCM100 configuration setting called "NMEA 2000 PGN Enable/Disable…", which is used to turn on and off specific messages that are transmitted by the DCM100. Read More
What are the dimensions of the DCM100 current transducers?
Viewed 2941 times since Tue, Nov 27, 2012
The DCM100 is packaged with a Hall Effect sensor (P/N: LEMHTA200-S) which is rated to measure currents up to 200 Amperes.If your application requires measurements exceeding 200 Amperes, Maretron offers additional sensors:400 Amperes measurement. Use... Read More
How do I display the DC State of Health on the DSM250 display?
Viewed 2940 times since Fri, Nov 7, 2008
You display the DC State of Health on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC State of Health and press enter. Scroll t... Read More
How do I display DC Current on the Maretron’s DSM250 display?
Viewed 2892 times since Fri, Nov 7, 2008
You display the DC Current on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC current and press enter. Scroll to "Data:" and pre... Read More
What configuration options are available for the DCM100?
Viewed 2823 times since Fri, Oct 28, 2016
Use the N2KAnalyzer software program or a Maretron DSM150, or Maretron DSM250 to perform Maretron Device level configuration. This article will show methods for configuring the DCM100 Using Maretron's N2KAnalyzer software tool. Pre-requisits:PC ... Read More
How do I reset the DCM100 to send the factory default NMEA 2000 messages (or PGNs)?
Viewed 2715 times since Fri, Nov 7, 2008
You reset the DCM100 to transmit the factory default messages using Maretron's DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and press enter. Scroll to the row cont... Read More
How do I display the DC Power on the DSM250 display?
Viewed 2696 times since Fri, Nov 7, 2008
You display the DC Power on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Power and press enter. Scroll to "Data:" and press e... Read More
What is the maximum voltage the DCM100 can sense?
Viewed 2688 times since Fri, Oct 15, 2010
The DCM100 can sense voltages up to 50VDC on terminals 5 and 6.The maximum voltage that can be supplied to power the DCM100 on is 32VDC on terminals 7 and 8.Pin NumberSignal NameConnection1IACurrent Sensor, Red Wire2IBCurrent Sensor, Green Wire3ICCur... Read More
What features does the DC/Battery Monitor (DCM100) have?
Viewed 2652 times since Tue, Jun 30, 2009
The Maretron DCM100 has the following features.NMEA 2000® InterfaceWaterproof ConnectorsSealed Waterproof EnclosureOpto-Isolated from NMEA 2000® Eliminating Potential Ground LoopsCan monitor DC Power Sources, Transmitting Voltage and CurrentCan monit... Read More
How do I display the DC Temperature on the DSM250 display?
Viewed 2499 times since Fri, Nov 7, 2008
You display the DC Temperature on the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the DC Temperature and press enter. Scroll to "Data:"... Read More
|