What type of information can be viewed on Maretron’s display products, and what products are required to generate the data to be displayed?
Viewed 25729 times since Tue, Oct 25, 2011
The Maretron Capability Matrix helps highlight the system features available for display when designing a system within N2KBuilder. To generate a system capability Matrix within N2KBuilder simply click on Tools, "Create Maretron Capability Matrix". ... Read More
Can Maretron devices be displayed on a Raymarine Seatalk NG network?
Viewed 10763 times since Wed, Feb 25, 2015
Yes, many of Maretron device's data can be displayed on Raymarine Chart-plotters With Seatalk and Seatalk ng functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the Maretron product's datashee... Read More
What are the voltage specifications for each Maretron device?
Viewed 8439 times since Thu, Dec 22, 2011
Maretron ModelDevice DescriptionNMEA2000 Operating VoltageEngine/Battery InterfaceCLM100 P/N: M000070 Current Loop Monitor9 to 32 Volts SSC200 P/N: M000001, M000021, M000022NMEA 2000 Solid State Compass HW 1.09 to 16 Volts SSC300 P/N: M000051NMEA ... Read More
Can Maretron’s sensor data be displayed on a Garmin network?
Viewed 8139 times since Mon, Jun 12, 2017
Yes, much of Maretron device's data can be shown on Garmin displays with “NMEA 2000” functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the Maretron product's datasheet specifically, the tran... Read More
How do I display the RAA100 rudder angle on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 7175 times since Thu, Jul 10, 2008
You display the RAA100 rudder angle on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the rudder angle and press ente... Read More
How do I set the RAA100 rudder number or instance using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 6233 times since Thu, Jul 10, 2008
You set the RAA100 rudder number or instance using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and press enter. Scroll to the row co... Read More
Using N2KAnalyzer, how do I recover a Maretron device?
Viewed 5418 times since Thu, Dec 22, 2011
Occasionally, a device can be in "boot mode" (represented in N2KAnalyzer by an orange highlight of the device's entry in the device list). This can happen due to a software update which fails due to network problems.A Maretron device that is not... Read More
Can Maretron’s sensor data be displayed on a Furuno CANBUS network?
Viewed 4752 times since Mon, Jun 12, 2017
Yes, much of Maretron device's data can be shown on Furuno displays with “CANBUS” functionality. Firstly, Maretron recommends that customers verify device compatibility by reviewing the Maretron product's datasheet specifically, the transmi... Read More
Why I can’t find a RAA100 rudder angle for display on Maretron’s DSM150, DSM200, or DSM250?
Viewed 3962 times since Fri, Jul 11, 2008
In order to keep the number of Maretron DSM150, DSM200, and DSM250 display menu items to a minimum (there is a possibility of more than 250 batteries, more than 250 engines, more than 250 rudders, etc.), the displays default to only a single rudder. ... Read More
Why doesn’t my rudder display read hard over when the rudder is hard over?
Viewed 3556 times since Thu, Jul 10, 2008
The rudder display may not read hard over even though the rudder is hard over if the resistive sensor is not turning throughout its entire range. You can fix this by either adjusting the resistive sensor to turn across its entire range or you can per... Read More
What information does the RAA100 provide?
Viewed 3466 times since Thu, Jul 10, 2008
The RAA100 provides the the rudder angle. Read More
How do I set the RAA100 configuration setting called "Gauge Resistance, + to sender" using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3406 times since Fri, Jul 11, 2008
You set the RAA100 "Gauge Resistance, + to sender" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and press enter. Scroll to the ... Read More
Can I set the RAA100 to accept the American standard for resistance values (i.e. 240 to 33 ohms) using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3383 times since Fri, Jul 11, 2008
Yes, it is possible to set the RAA100 to accept American standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "... Read More
What is an RAA100?
Viewed 3358 times since Fri, Jul 11, 2008
The RAA100 is a rudder angle adapter that converts an analog resistive sender into digital information, which is then broadcast over the NMEA 2000 where any NMEA 2000 compatible display can show the rudder angle. The RAA100 can be used with or withou... Read More
How do I set the RAA100 configuration setting called "Gauge Resistance, - to sender" using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3286 times since Thu, Jul 10, 2008
You set the RAA100 "Gauge Resistance, - to sender" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and press enter. Scroll to the ... Read More
What is the default calibration setting for the RAA100?
Viewed 3265 times since Fri, Jul 11, 2008
The RAA100 default calibration mode is set to accept the American standard resistance values of 240 to 30 ohms (240 ohms representing 60 degrees to port and 30 ohms representing 60 degrees to starboard). This can be changed using Maretron's DSM1... Read More
What messages (or PGNs) does the RAA100 transmit?
Viewed 3258 times since Fri, Jul 11, 2008
The RAA100 transmits the following message (or PGN):PGN 127245 - Rudder (Fields: 5 - Position) Read More
Is it possible to turn on or off RAA100 transmitted messages (or PGNs)?
Viewed 3211 times since Fri, Jul 11, 2008
Yes, it is possible to turn on and off the RAA100 transmitted messages (or PGNs) using Mareton's DSM150, DSM200, or DSM250 display. On the display, enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and pre... Read More
How do I reset the RAA100 to send the factory default messages (or PGNs)?
Viewed 3183 times since Fri, Jul 11, 2008
You reset the RAA100 to transmit the factory default messages using Maretron's DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and press enter. Scroll to the row cont... Read More
Can I set the RAA100 to accept the European standard for resistance values (i.e. 10 to 180 ohms) using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3164 times since Thu, Jul 10, 2008
Yes, it is possible to set the RAA100 to accept European standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "... Read More
How do I set the RAA100 operating mode using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3129 times since Thu, Jul 10, 2008
You set the RAA100 operating mode using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and press enter. Scroll to the row containing th... Read More
Can I custom calibrate the RAA100 for non-standard resistance sensors or can I do custom calibration for hard over points other than 60 degrees?
Viewed 2959 times since Thu, Jul 10, 2008
Yes, it is possible to calibrate the RAA100 to accept non-standard resistive sensors or to set custom hard over angles using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the followin... Read More
What is the RAA100 configuration setting "Gauge Resistance, + to sender" and "Gauge Resistance, - to sender"?
Viewed 2956 times since Thu, Jul 10, 2008
If the RAA100's operating mode is set to "NMEA 2000 & Analog Gauge", then it is important to configure the RAA100 with the gauge's resistances in order for the RAA100 to operate correctly. Please refer to the RAA100 User's Manual f... Read More
What is the RAA100 configuration setting "operating mode"?
Viewed 2922 times since Thu, Jul 10, 2008
The RAA100 can operate in one of two ways:without an analog gauge, which is referred to as the "NMEA 2000" mode, andwith an analog gauge, which is referred to as the "NMEA 2000 & Analog Gauge" modeThe default mode of operation is without an analo... Read More
What firmware changes have taken place on the Maretron RAA100?
Viewed 2646 times since Mon, May 16, 2011
2.0.2.3 2016-08-29):Corrected a problem where the device could lose its instance information after a power cycle (3968) 2.0.1.5 (2015-10)- Initial Release to support Hardware Version 21.4.10 (2009-08-12)- Corrected a problem with Maretron Label supp... Read More
Can I use the RAA100 if my hard over points are not 60 degrees?
Viewed 2642 times since Fri, Jul 11, 2008
Yes, you can use the RAA100 if the hard over points are not 60 degrees because the RAA100 can be custom calibrated for virtually any stop angle position. Hard over points can be calibrated over resistance values of 0 to 300 ohms. Read More
If the RAA100 is connected and configured to operate in the "NMEA 2000 & Analog Gauge" mode, how do I connect the wires to the back of the analog gauge?
Viewed 2594 times since Fri, Jul 11, 2008
You connect the RAA100 operating in the "NMEA 2000 & Analog Gauge" mode to the gauge in the following way:connect the black wire to the gauge ground terminalconnect the green wire to the gauge sensor terminalconnect the red wire to the gauge powe... Read More
How much electrical current does the RAA100 use?
Viewed 2573 times since Thu, Jul 10, 2008
The RAA100 draws less than 100mA (LEN=2) of current from the NMEA 2000 network. Read More
How much power does the RAA100 consume?
Viewed 2571 times since Fri, Jul 11, 2008
The RAA100 draws less than 100mA (LEN=2) of current from the NMEA 2000 network at 12 volts, or 1.2 watts of power. Read More
If the RAA100 is connected and configured to operate in the "NMEA 2000" mode (i.e., without an analog gauge), how do I connect the wires to the resistive sensor?
Viewed 2504 times since Thu, Jul 10, 2008
You connect the RAA100 operating in the NMEA 2000 mode (i.e., without analog gauge) to a resistive sensor in the following way:connect the black wire to the sensor ground terminalconnect the white wire to the sensor positive terminal Read More
I know that the RAA100 uses resistive rudder angle sensors; who manufactures resistive sensors?
Viewed 2494 times since Wed, Jun 6, 2012
The RAA100 is compatible with resistive rudder style sending unit. The brand, VDO manufacturers a sensor (Figure#1) that can output 10-180Ω of resistance range. Simply connect the RAA100's white and black wires to the VDO sender's positive(... Read More
What type of rudder senders does the RAA100 work with?
Viewed 1635 times since Thu, Jul 10, 2008
The RAA100 works with resistive rudder angle senders (i.e., the resistance changes with rudder angle). In the U.S., the standard for resistive senders is 240 to 30 ohms where 240 ohms represents 60 degrees to port and 30 ohms represents 60 degrees to... Read More
|