Does Maretron offer a DSM410 Gimble mount?
Viewed 23649 times since Wed, Jan 24, 2018
Does Maretron offer a DSM410 Gimbal mount?No, Maretron does not sell a DSM410 gimble mount.However, we do provide a 3D printer "STL" file (located in the attachment section below) that allows a 3D printer program to make the hardware on a 3D printer ... Read More
What Yanmar engine models is the EMS100 compatible with?
Viewed 14546 times since Thu, Mar 27, 2014
NOTE: The EMS100 has been discontinued and is no longer offered for sale. The EMS100 is suitable to work with Yanmar Engines which carry the Yazaki type connector.If your engine comes with a Yanmar panel, please note that all panels are not compatibl... Read More
What type of information can be viewed on Maretron’s display products, and what products are required to generate the data to be displayed?
Viewed 13042 times since Tue, Oct 25, 2011
The Maretron Capability Matrix helps highlight the system features available for display when designing a system within N2KBuilder. To generate a system capability Matrix within N2KBuilder simply click on Tools, "Create Maretron Capability Matrix". ... Read More
What are the voltage specifications for each Maretron device?
Viewed 12042 times since Thu, Dec 22, 2011
Maretron ModelDevice DescriptionNMEA2000 Operating VoltageEngine/Battery InterfaceCLM100 P/N: M000070 Current Loop Monitor9 to 32 Volts SSC200 P/N: M000001, M000021, M000022NMEA 2000 Solid State Compass HW 1.09 to 16 Volts SSC300 P/N: M000051NMEA ... Read More
I want to update my NMEA 2000 network to include fuel management data; which Maretron devices do I need?
Viewed 9698 times since Fri, Mar 8, 2013
The FFM100 can update your existing NMEA2000 network to include engine fuel rate. Several components are needed to offer you calculative information for Fuel management such as distance to empty, time to empty, and fuel consumption, to name a few. T... Read More
How do I show comprehensive bilge information on Maretron’s DSM150 or DSM250 displays?
Viewed 7420 times since Thu, May 30, 2013
Knowledge base Article 578 showed how to do comprehensive bilge monitoring using Maretron's Run Indicator Module (RIM100) and a Switch Indicator Module (SIM100). This article shows how the monitored information from article 578 can be displayed ... Read More
How do I configure an EMS100 that is connected to a Yanmar engine?
Viewed 6499 times since Tue, Sep 1, 2009
NOTE: The EMS100 has been discontinued and is no longer offered for sale.To configure the EMS100 using the DSM250, start from the favorite screen mode and press the enter key or the far right hand button, scroll to configuration and press enter, scro... Read More
How do I set up the EMS100 for my Yanmar engine?
Viewed 5281 times since Tue, May 10, 2011
In order to setup an EMS100 several things must be known.What senders have been installed on the engine?What type of engine gauge panel is installed with the engine?Where is the factory interface available for the EMS100 engine harness to tee into?On... Read More
Which Maretron products are required for me to display true wind referenced to ground speed?
Viewed 5172 times since Wed, Apr 10, 2013
In order to display true wind referenced to ground speed you will need a WSO100, a GPS200, a SSC200, and a display capable of computing true wind referenced to ground speed. The WSO100 measures the apparent wind while the GPS200 provides Speed Over G... Read More
I have configured my DSM410 or DSM250; how do I perform a backup?
Viewed 4662 times since Tue, Feb 26, 2013
Now that you have configured your DSM250 or DSM410 just the way you want it. Once complete you can backup all your work using the following method: You must have several items installed on the NMEA 2000 network and your PC to begin:USB100 or IPG100D... Read More
How do I show simple bilge information on Mareton’s DSM150 or DSM250 displays?
Viewed 4596 times since Sat, Apr 27, 2013
Knowldege base article 578 showed how to do simple bilge monitoring using Maretron's Run Indicator Module (RIM100). This article shows how the monitored information from article 578 can be displayed on Maretron's DSM150 and DSM250 displays.... Read More
What Maretron products are recommended for displaying Yanmar engine information?
Viewed 4444 times since Sat, Sep 5, 2009
NOTE: The EMS100 has been discontinued and is no longer offered for sale.There are several ways to view Yanmar engine information over an NMEA 2000 network, one of which is using the Maretron dedicated color display (DSM250). The following diagram sh... Read More
I navigate using true heading and not magnetic heading; how do I use the SSC200 compass and N2KView software to view my heading in true?
Viewed 4403 times since Fri, Jul 18, 2008
The SSC200 compass outputs heading information in magnetic form and before N2KView can display true heading, the variation must be known. One source of variation is the Maretron GPS antenna/receiver (GPS200). If an SSC200 and GPS200 are connected tog... Read More
Can Maretron’s DSM150 or DSM250 display or N2KAnalyzer configure certain Airmar transducers?
Viewed 4178 times since Thu, Mar 31, 2011
Yes, Maretron's multi-function color displays (DSM150 and DSM250) or Maretron's N2KAnalyzer configuration tool (used in conjunction with the USB100 or IPG100 gateway) can be used to configure certain Airmar transducers. Please see the attac... Read More
Which Maretron products are necessary in order to display true wind referenced to water speed?
Viewed 3981 times since Wed, Apr 10, 2013
In order to display true wind referenced to water speed, you will need a WSO100, a DST110, and a display capable of computing true wind referenced to water speed. The WSO100 measures the apparent wind while the DST110 provides Speed Through Water (ST... Read More
What is the SMS100 Status message? Which Maretron components do I need?
Viewed 3897 times since Thu, Jun 6, 2013
The SMS100 Status Message is a text message you can receive from the SMS100 containing key pieces of information regarding your vessel. When the SMS100 is installed, you can text the word "Status" to your SMS100 cellular number and receive a respons... Read More
What information is available from the temperature monitor (TMP100) and can be viewed on Maretron’s displays?
Viewed 3697 times since Fri, Jun 21, 2013
The TMP100 is capable of transmitting the following information:Sea TemperatureOutside TemperatureInside TemperatureEngine Room TemperatureMain Cabin TemperatureLive Well TemperatureBait Well TemperatureRefrigeration TemperatureHeating System Temper... Read More
How do I display the GPS Course Over Ground (COG) using Maretron’s DSM150 or DSM250 display?
Viewed 3656 times since Tue, Jun 17, 2008
You display the GPS100 Course Over Ground (COG) information on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the CO... Read More
Which Maretron products are necessary in order to display apparent wind?
Viewed 3620 times since Wed, Apr 10, 2013
In order to display apparent wind, you only need a WSO100 and a display capable of showing apparent wind. Maretron's DSM150/250 dedicated NMEA 2000 displays or Maretron's N2KView PC software are capable of displaying apparent wind. Read More
I have installed the TLM100 and see incorrect tank levels; what does this mean?
Viewed 3522 times since Sat, Aug 27, 2011
The TLM100 uses an ultrasonic signal to determine a distance measurement from sensor to level.The tank application must be compatible with the TLMXXX measurement technology. If you have already installed a TLMXXX and received unexpected results, the... Read More
What sensors does Maretron recommend for basic navigation?
Viewed 3507 times since Wed, Apr 10, 2013
A standard Maretron NMEA2000 navigation sensor network consists of the following components:Compass: SSC200GPS: GPS200Depth Speed Water: DST110Weather: WSO100Display: DSM150System Capabilities:Wind ApparentSpeed over groundCourse over groundSpeed thr... Read More
Why I can’t find a RAA100 rudder angle for display on Maretron’s DSM150, DSM200, or DSM250?
Viewed 3464 times since Fri, Jul 11, 2008
In order to keep the number of Maretron DSM150, DSM200, and DSM250 display menu items to a minimum (there is a possibility of more than 250 batteries, more than 250 engines, more than 250 rudders, etc.), the displays default to only a single rudder. ... Read More
What type of watermakers are compatible with the DSM250?
Viewed 3443 times since Fri, Oct 2, 2009
What type of watermakers arecompatible with the DSM250? &n... Read More
How do I display the J2K100 engine fuel rate on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3328 times since Thu, Jan 14, 2010
You display the J2K100 engine fuel rate on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the fuel rate and press ent... Read More
What is the procedure for testing the ALM100 Annunciator?
Viewed 3271 times since Thu, Jan 8, 2015
The procedure for testing an ALM100 can be performed using the following Maretron User Interface products:DSM150/DSM250:Go to Main Menu-->Scroll to Configuration-->Select "Device Configuration"-->Select the ALM00 you wish to test-->Scroll to "Test An... Read More
How do I display the J2K100 engine oil pressure on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3266 times since Thu, Jan 14, 2010
You display the J2K100 engine oil pressure on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the oil pressure and pre... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a DST100 configuration setting called "Transducer Depth Offset:"; what is this?
Viewed 3229 times since Mon, Jun 25, 2012
Transducer offset is eitherthe distance from the waterline to the transducer (DST100 bottom surface), orthe distance from the transducer to the bottom of the vessel.Maretron display products (DSM150, DSM200, DSM250, and N2KView) add the transducer of... Read More
How do I display the J2K100 engine boost pressure on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3223 times since Thu, Jan 14, 2010
You display the J2K100 engine boost pressure on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the boost pressure and... Read More
I see that Maretron’s DSM150, DSM200 and DSM250 displays have a WSO100 configuration setting called "Installation Offset Calibration..."; what is this?
Viewed 3184 times since Mon, Jul 21, 2008
Maretron's DSM150, DSM200 and DSM250 displays have a WSO100 configuration setting called "Installation Offset Calibration...", which is used to electronically align the WSO100 with the vessel. Although the WSO100 can be mechanically aligned with... Read More
Using N2KAnalyzer, how do I recover a Maretron device?
Viewed 3179 times since Thu, Dec 22, 2011
Occasionally, a device can be in "boot mode" (represented in N2KAnalyzer by an orange highlight of the device's entry in the device list). This can happen due to a software update which fails due to network problems.A Maretron device that is not... Read More
How do I set the J2K100 configuration setting called "J1939 Source Address:" using Maretron’s DSM150 or DSM250 display?
Viewed 3158 times since Thu, Jan 14, 2010
You set the J2K100 configuration setting called "J1939 Source Address:" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and press ... Read More
How do I clear the WSO100 atmospheric pressure offset using Maretron’s DSM150 or DSM250 display?
Viewed 3155 times since Sat, Aug 2, 2008
You clear the WSO100 atmospheric pressure offset using Maretron's DSM150 or DSM250 display in the following way:Enter menu mode, scroll to "Configuration…" and press < Enter >Scroll to "Device Configuration…" and press < Enter >Scroll to the row... Read More
How do I display the J2K100 generator average line-neutral AC RMS voltage on Maretron’s DSM150 or DSM250 display?
Viewed 3127 times since Thu, Jan 14, 2010
You display the J2K100 generator average line-neutral AC voltage on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view th... Read More
How do I clear the WSO100 installation offset using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3108 times since Sat, Aug 2, 2008
You clear the WSO100 installation offset using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, scroll to "Configuration…" and press < Enter >Scroll to "Device Configuration…" and press < Enter >Scroll to the ro... Read More
How do I set a "Device Instance" for a Maretron sensor using the DSM250?
Viewed 3094 times since Tue, Sep 1, 2009
To set a "Device Instance" for a Maretron sensor using the DSM250, simply press the enter key (far right hand button) to view the "Menu Mode", scroll to "Configuration", hit enter, select "Device Configuration", hit enter, scroll to the desired devic... Read More
How do I display the J2K100 engine hours on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3065 times since Thu, Jan 14, 2010
You display the J2K100 engine hours on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the hours and press enter. Scro... Read More
How do I display the WSO100 apparent wind on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3053 times since Thu, Jul 10, 2008
You display the WSO100 apparent wind on a DSM150, DSM200, or DSM250 in the following way.Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the apparent wind and press <... Read More
I navigate using magnetic heading and not true heading; how do I use the SSC200 compass and Maretron’s DSM150, DSM200, or DSM250 display to view my heading in magnetic?
Viewed 3042 times since Thu, Jun 19, 2008
The SSC200 compass outputs heading information in magnetic format, so you just need to properly configure the DSM150, DSM200, or DSM250 to display heading in magnetic. To view magnetic heading on the DSM150, DSM200, or DSM250, do the following:Enter ... Read More
How do I display the J2K100 engine oil temperature on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3014 times since Thu, Jan 14, 2010
You display the J2K100 engine oil temperature on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the oil temperature a... Read More
How do I display the J2K100 transmission oil pressure on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3002 times since Thu, Jan 14, 2010
You display the J2K100 transmission oil pressure on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the oil pressure a... Read More
How do I display the J2K100 generator average line-line AC voltage on Maretron’s DSM150 or DSM250 display?
Viewed 2988 times since Thu, Jan 14, 2010
You display the J2K100 generator average line-line AC voltage on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the v... Read More
How do I display the TLA100, TLM100, TLM150, or TLM200 tank capacity on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2984 times since Fri, Jun 20, 2008
You display the TLA100 tank capacity on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the tank capacity and press <... Read More
How do I know if the GPS100 is locked on and producing a position fix using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2977 times since Tue, Jun 17, 2008
You display whether or not the GPS100 has a fix on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the GPS status and... Read More
How do I set the J2K100 configuration setting called "NMEA 2000 Engine Instance:" using Maretron’s DSM150 or DSM250 display?
Viewed 2968 times since Thu, Jan 14, 2010
You set the J2K100 configuration setting called "NMEA 2000 Engine Instance:" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and p... Read More
What is the default calibration setting for the TLA100?
Viewed 2965 times since Fri, Jun 20, 2008
The TLA100 default calibration mode is set to accept the American standard resistance values of 240 to 30 ohms (240 ohms representing empty and 30 ohms representing full). This can be changed using Maretron's DSM150, DSM200, or DSM250 display to... Read More
Can I turn On and Off loads connected to the DCR100 using the DSM150 or DSM250?
Viewed 2952 times since Thu, May 5, 2011
Yes, you can turn On and Off loads connected to the DCR100 using the DSM150 or DSM250. To do so, you should understand a few things about the DSM150 or DSM250 and its favorite screens. First, you need to understand how to setup a favorite screen with... Read More
Why doesn’t my rudder display read hard over when the rudder is hard over?
Viewed 2949 times since Thu, Jul 10, 2008
The rudder display may not read hard over even though the rudder is hard over if the resistive sensor is not turning throughout its entire range. You can fix this by either adjusting the resistive sensor to turn across its entire range or you can per... Read More
I see that Maretron’s DSM150, DSM200 and DSM250 displays have TLA100 configuration settings called "Gauge Resistance, + to sender:" and "Gauge Resistance, - to sender:"; what are these?
Viewed 2935 times since Mon, Jun 25, 2012
If the TLA100's operating mode is set to "NMEA 2000 & Analog Gauge", then it is important to configure the TLA100 with the gauge's resistances in order for the TLA100 to operate correctly. Please refer to the TLA100 Users Manual for a d... Read More
How do I display the J2K100 engine percent load on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2928 times since Thu, Jan 14, 2010
You display the J2K100 engine percent load on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the percent load and pre... Read More
How do I display a SIM100 channel on the Maretron DSM250?
Viewed 2905 times since Wed, Dec 23, 2009
You display a SIM100 channel using the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup…" and press enter. Scroll to the favorite screen where you would like to view the indicator channel*.* and press enter.... Read More
How do I display the SSC200 magnetic heading on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2904 times since Tue, Jul 22, 2008
You display the SSC200 magnetic heading information on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the magnetic h... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Type:"; what is this?
Viewed 2903 times since Sun, Jun 22, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Type", which is used to set the type of fluid so subsequent transmissions from the TLA100 can identify the fluid or tank type. Read More
What firmware changes have taken place on the Maretron DSM250?
Viewed 2892 times since Wed, Apr 16, 2014
DSM250 firmware versions: DSM250 1.7.5.3(2018-01-24):Correctly display invalid data in LAT/LON screen (4405)Correctly display PGN 129029 data in LAT/LON screen (4418)Fixed crashing issue in control mode while setting anchor position (4421)Corrected a... Read More
How do I set the TLA100 tank capacity using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2889 times since Mon, Jun 25, 2012
You set the TLA100 tank capacity using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Configuration:" and press < Enter >Scroll to the row contai... Read More
How do I display the J2K100 generator average AC frequency on Maretron’s DSM150 or DSM250 display?
Viewed 2884 times since Thu, Jan 14, 2010
You display the J2K100 generator average AC frequency on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the frequency... Read More
How do I display the J2K100 engine coolant pressure on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2873 times since Thu, Jan 14, 2010
You display the J2K100 engine coolant pressure on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the coolant pressure... Read More
How do I display the J2K100 transmission oil temperature on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2872 times since Thu, Jan 14, 2010
You display the J2K100 transmission oil temperature on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the oil tempera... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called "J1939 Diagnostic Messages:"; what is this?
Viewed 2866 times since Thu, Jan 14, 2010
Maretron's DSM150, DSM200,and DSM250 displays have a J2K100 configuration setting called "J1939 Diagnostic Messages:" which is used to configure the J2K100 to pass diagnostic messages from the J1939 network through to the NMEA 2000 network. Nor... Read More
How do I display the TLA100 tank level on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2856 times since Wed, Jul 9, 2008
You display the TLA100 tank level on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the tank level and press < Enter... Read More
How do I set the TLA100 tank number or instance using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2837 times since Fri, Jun 20, 2008
You set the TLA100 tank number or instance using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Configuration:" and press < Enter >Scroll to the ... Read More
How do I display UTC from the GPS100 on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2831 times since Mon, Jun 25, 2012
You display UTC from the GPS100 on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode (press the key or far right button), scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to vie... Read More
How do I set the RAA100 configuration setting called "Gauge Resistance, + to sender" using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2829 times since Fri, Jul 11, 2008
You set the RAA100 "Gauge Resistance, + to sender" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and press enter. Scroll to the ... Read More
What information is available from the J1939 to NMEA 2000 Bridge (J2K100) and can be viewed on Maretron’s displays?
Viewed 2813 times since Mon, Jun 24, 2013
The J2K100 is capable of transmitting the following information:PGN 65030AC Generator CurrentAC Generator FrequencyAC Generator VoltageEngine parameters 127488, 127489TachometerEngine HoursCoolant PressureCoolant Water TemperatureEngine Oil Pressure... Read More
How do I reset the J2K100 to send the factory default NMEA 2000 messages (or PGNs)?
Viewed 2812 times since Thu, Jan 14, 2010
You reset the J2K100 to transmit the factory default messages using Maretron's DSM250 display in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and press enter. Scroll to the row cont... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Number:"; what is this?
Viewed 2810 times since Thu, Jun 19, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Number", which is used to set the tank number so subsequent transmissions from the TLA100 can identify which tank of a particular fluid is being repo... Read More
How do I display the J2K100 engine fuel pressure on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2798 times since Thu, Jan 14, 2010
You display the J2K100 engine fuel pressure on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the fuel pressure and p... Read More
How do I display the J2K100 transmission gear on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2783 times since Thu, Jan 14, 2010
You display the J2K100 transmission gear on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the gear and press enter. ... Read More
How do I configure a channel on the TMP100 using Maretron’s DSM250?
Viewed 2779 times since Fri, Jun 11, 2010
You configure a channel on the TMP100 in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and press enter. Scroll to the row containing TMP100 and press enter. Select one of six channel... Read More
What are the operating modes of the DSM250?
Viewed 2779 times since Tue, Oct 6, 2009
The DSM250 operatesin one of two operating modes. These two modes are called the Menu mode, andthe Favorite Screen Mode. Once the DSM250 is powered up and the disclaimer hasbeen acknowledged, the DSM250 starts in the favorite screen mode. At any time... Read More
How do I display the J2K100 engine coolant temperature on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2762 times since Sat, Jun 25, 2011
You display the J2K100 engine coolant temperature on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the coolant tempe... Read More
How do I set the J2K100 configuration setting called "NMEA 2000 Transmission Instance:" using Maretron’s DSM150 or DSM250 display?
Viewed 2754 times since Thu, Jan 14, 2010
You set the J2K100 configuration setting called "NMEA 2000 Transmission Instance:" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?"... Read More
How do I set the TLA100 tank type using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2738 times since Fri, Jun 20, 2008
You set the TLA100 tank type using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Configuration:" and press < Enter >Scroll to the row containing... Read More
Can I use the DSM150 or DSM250 to configure a DCR100?
Viewed 2707 times since Tue, May 10, 2011
Yes, you can use a DSM150 or DSM250 to configure a DCR100. Please watch the following video to see how it's done. Read More
How do I reset the RAA100 to send the factory default messages (or PGNs)?
Viewed 2700 times since Fri, Jul 11, 2008
You reset the RAA100 to transmit the factory default messages using Maretron's DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and press enter. Scroll to the row cont... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called "Reset Factory Defaults"; what is this?
Viewed 2697 times since Thu, Jan 14, 2010
Maretron's DSM150, DSM200,and DSM250 displays have a J2K100 configuration setting called "Reset Factory Defaults" which is used to return the J2K100 to its factory settings. Resetting the J2K100 to factory defaults sets the J1939 source address ... Read More
Can I set the RAA100 to accept the American standard for resistance values (i.e. 240 to 33 ohms) using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2693 times since Fri, Jul 11, 2008
Yes, it is possible to set the RAA100 to accept American standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "... Read More
How do I set the J2K100 configuration setting called "J1939 Diagnostic Messages:" using Maretron’s DSM150 or DSM250 display?
Viewed 2689 times since Thu, Jan 14, 2010
You set the J2K100 configuration setting called "J1939 Diagnostic Messages:" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and p... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called "NMEA 2000 PGN Enable/Disable..."; what is this?
Viewed 2684 times since Thu, Jan 14, 2010
Maretron's DSM150, DSM200,and DSM250 displays have a J2K100 configuration setting called "NMEA 2000 PGN Enable/Disable?" which is used to turn on and off specific messages that are transmitted by the J2K100. Read More
Why does my GPS100 transmit the wrong year?
Viewed 2674 times since Sat, Aug 2, 2008
There are rare occasions when the GPS100 will transmit an incorrect date as reflected in the year. This can happen if the GPS signals are weak or corrupted and the GPS100 incorrectly interprets time from the satellites. You can fix this by resetting ... Read More
How do I set the RAA100 configuration setting called "Gauge Resistance, - to sender" using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2673 times since Thu, Jul 10, 2008
You set the RAA100 "Gauge Resistance, - to sender" using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and press enter. Scroll to the ... Read More
How do I clear the DST100 Speed Through Water (STW) calibration using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2672 times since Mon, Aug 4, 2008
You clear the Speed Through Water (STW) calibration on individual DSM150s, DSM200s, or DSM250s in the following way.Enter the menu mode, scroll to "Configuration..." and press < Enter >Scroll to "Device Configuration..." and press < Enter >Scroll to ... Read More
What are the dimensions for the DSM410?
Viewed 2667 times since Thu, Jun 1, 2017
For a printable DSM410 mounting template, download the PDF under the attachments section below. Read More
How do I set the WSO100 wind damping period using Maretron’s DSM250 display?
Viewed 2661 times since Wed, Aug 6, 2008
You set the WSO100 wind damping period using Maretron's DSM150 or DSM250 display in the following way:Enter menu mode, scroll to "Configuration…" and press < Enter >Scroll to "Device Configuration…" and press < Enter >Scroll to the row containin... Read More
What type of tank senders does the TLA100 work with?
Viewed 2661 times since Fri, Jun 20, 2008
The TLA100 works with resistive tank senders (i.e., the resistance changes with tank level). In the U.S., the standard for resistive senders is 240 to 30 ohms where 240 ohms represents empty and 30 ohms represents full. The European standard for resi... Read More
How do I set the TLA100 configuration setting called "Gauge Resistance, - to sender" using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2659 times since Fri, Jun 20, 2008
You set the TLA100 "Gauge Resistance, - to sender" using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Configuration:" and press < Enter >Scroll... Read More
What is the default calibration setting for the RAA100?
Viewed 2655 times since Fri, Jul 11, 2008
The RAA100 default calibration mode is set to accept the American standard resistance values of 240 to 30 ohms (240 ohms representing 60 degrees to port and 30 ohms representing 60 degrees to starboard). This can be changed using Maretron's DSM1... Read More
How do I display the J2K100 generator average AC current on Maretron’s DSM150 or DSM250 display?
Viewed 2636 times since Thu, Jan 14, 2010
You display the J2K100 generator average AC current on a DSM150, DSM200, or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to view the current and... Read More
How do I display the TLA100 tank remaining on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2628 times since Fri, Jun 20, 2008
You display the TLA100 tank remaining on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the tank remaining and press... Read More
Can I set the RAA100 to accept the European standard for resistance values (i.e. 10 to 180 ohms) using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2621 times since Thu, Jul 10, 2008
Yes, it is possible to set the RAA100 to accept European standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way. Enter menu mode, scroll to "... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a DST100 configuration setting called "Clear Speed Calibration:"; what is this?
Viewed 2618 times since Sun, Jun 22, 2008
Maretron's DSM200 and DSM250 displays have a DST100 configuration setting called "Clear Speed Calibration:", which is used wipe out or clear the multiplier used by the displays to adjust the Speed Through Water (STW) value coming from a DST100. Read More
How do I display the DC Time Remaining on the DSM150 or DSM250 display?
Viewed 2613 times since Fri, Nov 7, 2008
You display the DC Time Remaining on the DSM150 or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press Enter. Scroll to the favorite screen where you would like to view the DC Time Remaining and press Enter. S... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Reset Factory Defaults"; what is this?
Viewed 2603 times since Mon, Jul 21, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Reset Factory Defaults", which is used to return the SSC200 to its factory settings. Resetting the SSC200 erases the deviation table, clears the installat... Read More
Is it possible to turn on or off RAA100 transmitted messages (or PGNs)?
Viewed 2599 times since Fri, Jul 11, 2008
Yes, it is possible to turn on and off the RAA100 transmitted messages (or PGNs) using Mareton's DSM150, DSM200, or DSM250 display. On the display, enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Configuration…" and pre... Read More
What information is available from the fluid pressure monitor (FPM100) and can be viewed on Maretron’s displays?
Viewed 2591 times since Fri, Jun 21, 2013
The FPM100 is capable of transmitting the following information: Pressures:Atmospheric PressureWater PressureSteam PressureCompressed Air PressureHydraulic PressureUser Defined 129 to 144Tank Types:Fuel Level, CapacityFresh Water Level, CapacityWast... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a DST100 configuration setting called "Speed Calibration..."; what is this?
Viewed 2589 times since Sun, Jun 22, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a DST100 configuration setting called "Speed Calibration...", which is used to set a multiplier for adjusting the Speed Through Water (STW) coming from the DST100. Read More
How do I label the title of a window on a DSM250 Favorite Screen?
Viewed 2589 times since Mon, Mar 30, 2009
You can label a data window in a favorite screen the following way: hit enter for main menus, scroll to "Favorite Screen Setup", enter, scroll to a favorite screen you wish to configure, enter, scroll to title, enter, scroll to custom, enter. You wil... Read More
How do I display the GPS100 moon phase on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2587 times since Tue, Jun 17, 2008
The GPS100 doesn't actually compute and transmit the phase of the moon over an NMEA 2000 network. However, the DSM150, DSM200, and DSM250 receive enough information from the GPS100 (time and position) to compute the phase of the moon. You displa... Read More
How do I reset the GPS100 to send the factory default NMEA 2000 messages (or PGNs)?
Viewed 2587 times since Tue, Jun 17, 2008
You reset the GPS100 to transmit the factory default messages using Maretron's DSM150 or DSM250 display in the following way.Enter menu mode, scroll to "Configuration..." and press < Enter >Scroll to "Device Configuration..." and press < Enter >... Read More
How do I reset the DST100 trip log using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2584 times since Sun, Jun 22, 2008
You reset the DST100 trip log using a DSM150, DSM200, or DSM250 in the following way.Enter the menu mode, scroll to "Configuration..." and press < Enter >Scroll to "Device Configuration..." and press < Enter >Scroll to the DST100 and press < Enter >S... Read More
How do I set the TLA100 configuration setting called "Gauge Resistance, + to sender:" using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2583 times since Mon, Jun 25, 2012
You set the TLA100 "Gauge Resistance, + to sender" using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Configuration:" and press < Enter >Scroll... Read More
How do I calibrate the SSC200 pitch to read zero using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2577 times since Fri, Jul 18, 2008
You can calibrate the SSC200 pitch to read zero when the vessel is sitting flat in the water using a DSM150, DSM200, or DSM250 display. To zero the pitch, enter menu mode, scroll to "Configuration..." and press enter. Scroll to "Device Configuration.... Read More
Why can’t I find a particular TLA100 tank level for display on Maretron’s DSM150, DSM200, or DSM250?
Viewed 2556 times since Fri, Jun 20, 2008
In order to keep the number of Maretron DSM150, DSM200, and DSM250 display menu items to a minimum (there is a possibility of more than 250 batteries, more than 250 engines, more than 250 tanks, etc.), the displays default to only few instances of ta... Read More
Is it possible to turn on or off J2K100 NMEA 2000 transmitted messages (or PGNs)?
Viewed 2551 times since Thu, Jan 14, 2010
Yes, it is possible to turn on and off the J2K100 transmitted messages (or PGNs) using Maretron's DSM150, DSM200, or DSM250 display. On the display, enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and pr... Read More
How do I set the TLA100 operating mode using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2546 times since Fri, Jun 20, 2008
You set the TLA100 operating mode using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Configuration:" and press < Enter >Scroll to the row conta... Read More
When I am creating a favorite screen on the DSM150 or DSM250, I see an "Instance:" menu item; what does this mean?
Viewed 2545 times since Thu, Mar 5, 2009
NMEA 2000 allows multiple devices of the same type to be connected on a network at one time. The "Instance:" menu item allows you to choose a particular device for display on the DSM150 or DSM250. For example, if there were two GPS antennas on the ne... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Magnetic Deviation Calibration?"; what is this?
Viewed 2543 times since Thu, Jun 19, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Magnetic Deviation Calibration...", which is used to calibrate the compass to account for sources of magnetic deviation on the vessel. Read More
Can I do a custom calibration for non-standard resistance sensors or odd shaped tanks?
Viewed 2534 times since Thu, Jun 19, 2008
Yes, it is possible to program the TLA100 to accept non-standard resistive sensors or odd shaped tanks using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way:... Read More
How do I set up my SMS100 address book using Maretron displays?
Viewed 2529 times since Thu, Jun 6, 2013
SMS100 Operational Requirements: Working NMEA2000 networkSMS100 text moduleDSM150/DSM250 display with firmware version 1.4.18.8 or higher N2KView software/hardware versions 3.6.2 or higherThe SMS100 requires a Maretron display to produce alert messag... Read More
How do I clear the WSO100 outside humidity offset using Maretron’s DSM150 or DSM250 display?
Viewed 2528 times since Sat, Aug 2, 2008
You clear the WSO100 outside humidity offset using Maretron's DSM150 or DSM250 display in the following way:Enter menu mode, scroll to "Configuration…" and press < Enter >Scroll to "Device Configuration…" and press < Enter >Scroll to the row con... Read More
How do I clear the WSO100 outside temperature offset using Maretron’s DSM150 or DSM250 display?
Viewed 2525 times since Mon, Jun 25, 2012
You clear the WSO100 outside temperature offset using Maretron's DSM150 or DSM250 display in the following way:Enter menu mode, scroll to "Configuration…" and press < Enter >Scroll to "Device Configuration…" and press < Enter >Scroll to the row ... Read More
I see that the FPM100 has an accessory for measuring pressures in the range of -1Bar to 1 Bar. Can I use this sensor to monitor my fuel filters?
Viewed 2522 times since Thu, Dec 18, 2014
Yes, the FPM100 can transmit vacuum pressure data on the NMEA2000 bus by using Maretron sensor part number PT-V-0-1BAR-01. This sensor must be installed on the vacuum side of your fuel filter to help you determine fuel filter health displayed on a Ma... Read More
How do I display the GPS100 local time on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2510 times since Tue, Jun 17, 2008
You display the GPS100 local time information on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the local time and p... Read More
How do I display the GPS100 local date on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2494 times since Tue, Jun 17, 2008
You display the GPS100 local date information on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the local date and p... Read More
How do I make the SSC200 agree with other compasses on the vessel, or, in other words, how do I align the SSC200 with the boat?
Viewed 2492 times since Mon, Jun 25, 2012
The SSC200 compass is aligned with the vessel by pointing the arrow shown on the top of the compass towards the bow. There are alternative mounting options, which can be found the users manual. Once you have performed magnetic deviation calibration o... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Variation Source:"; what is this?
Viewed 2490 times since Thu, Jun 19, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Variation Source:", which is used to tell the compass from where it should receive the magnetic variation for subsequent transmission of the heading (HDT)... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Capacity:"; what is this?
Viewed 2484 times since Thu, Jun 19, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Capacity", which is used to set the amount of fluid that the tank can hold. Subsequent transmissions from the TLA100 can then identify how much fluid... Read More
How do I display the GPS100 latitude and longitude or position using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2465 times since Sun, Jun 22, 2008
You display the GPS100 position information on a DSM150, DSM200, or DSM250 in the following way.Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the position and press... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Invert Installation:"; what is this?
Viewed 2458 times since Tue, Jun 17, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Invert Installation:", which is used to describe the orientation of the compass relative to the vessel. For example, the compass can be mounted upside dow... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a GPS100 configuration setting called "Cold Start GPS Engine"; what is this?
Viewed 2451 times since Tue, Jun 17, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a GPS100 configuration setting called "Cold Start GPS Engine", which is used to force the GPS100 to forget what it knew the last time it acquired a lock and to start a new position fix by reacq... Read More
How do I display the GPS100 UTC date on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2447 times since Tue, Jun 17, 2008
You display the GPS100 UTC date information on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the UTC date and press... Read More
Is it possible to turn on or off SSC200 NMEA 2000 transmitted messages (or PGNs)?
Viewed 2432 times since Mon, Jun 25, 2012
Yes, it is possible to turn on and off the SSC200 transmitted messages (or PGNs) using Maretron's DSM150, DSM200, or DSM250 display. On the display:Enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Configuration?" ... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a GPS100 configuration setting called "Reset Factory Defaults"; what is this?
Viewed 2429 times since Thu, Mar 5, 2009
Maretron's DSM150, DSM200, and DSM250 displays have a GPS100 configuration setting called "Restore Factory Defaults", which is used to return the GPS100 to its factory settings. Resetting the GPS100 resets the SBAS mode back to enabled, resets t... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Operating Mode:"; what is this?
Viewed 2422 times since Thu, Jun 19, 2008
The TLA100 can operate in one of two ways:without an analog gauge which is referred to as the "NMEA 2000" modewith an analog gauge which is referred to as the "NMEA 2000 & Analog Gauge" modeThe default mode of operation is without an analog gauge... Read More
How do I reset the SSC200 to send the factory default NMEA 2000 messages (or PGNs)?
Viewed 2421 times since Thu, Jun 19, 2008
You reset the SSC200 to transmit the factory default messages using Maretron's DSM150 or DSM250 display in the following way:Enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Configuration:" and press < Enter >Scro... Read More
Is it possible to turn on or off GPS100 NMEA 2000 transmitted messages (or PGNs)?
Viewed 2415 times since Tue, Jun 17, 2008
Yes, it is possible to turn on and off the GPS100 transmitted messages (or PGNs) using Maretron's DSM150, DSM200, or DSM250 display. On the display:enter menu mode, scroll to "Configuration..." and press < Enter >Scroll to "Device Configuration.... Read More
How do I display the GPS100 sunrise time on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2407 times since Tue, Jun 17, 2008
The GPS100 doesn't actually compute and transmit the sunrise time over an NMEA 2000 network. However, the DSM200 and DSM250 receive enough information from the GPS100 (time and position) to compute the sunrise time. You display the sunrise time ... Read More
Is it possible to turn on or off SSC200 NMEA 0183 transmitted sentences?
Viewed 2395 times since Thu, Jun 19, 2008
Yes, it is possible to turn on and off the SSC200 transmitted NMEA 0183 sentences or messages using Maretron's DSM150, DSM200, or DSM250 display. On the display:Enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Con... Read More
How do I display the GPS100 status using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2387 times since Tue, Jun 17, 2008
You display the GPS100 status information on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the status and press < E... Read More
How do I calibrate the SSC200 roll to read zero using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2380 times since Tue, Jun 17, 2008
You can calibrate the SSC200 roll to read zero when the vessel is sitting flat in the water using a DSM150, DSM200, or DSM250 display. To zero the roll:Enter menu mode, scroll to "Configuration..." and press < Enter >Scroll to "Device Configuration..... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Installation Offset Calibration?"; what is this?
Viewed 2357 times since Thu, Jun 19, 2008
Maretron'sDSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Installation Offset Calibration...", which is used to electronically align the compass with the vessel. Although there is an arrow on the compass label, it... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Rate of Turn Damping Period:"; what is this?
Viewed 2356 times since Thu, Jun 19, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Rate of Turn Damping Period:", which is used to smooth the rate of turn indication. The rate of turn indication uses the rate of turn gyro found within th... Read More
How do I display the SSC200 rate of turn on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2353 times since Tue, Jul 22, 2008
You display the SSC200 rate of turn on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view rate of turn and press < Enter... Read More
How do I calibrate the SSC200 rate of turn using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2350 times since Thu, Jun 19, 2008
You calibrate the SSC200 rate of turn using a DSM150, DSM200, or DSM250. To calibrate the rate of turn using one of the displays:Enter menu mode, scroll to "Configuration..." and press < Enter >Scroll to "Device Configuration..." and press < Enter >S... Read More
How do I operate the DSM250 power button?
Viewed 2335 times since Tue, Sep 1, 2009
The far left hand button is the power button. While the DSM250 is off, press the power button once to turn the DSM250 on. While the DSM250 is starting up, you will see a screen indicating that the DSM250 is booting up. Once the DSM250 has initialized... Read More
Is it possible to change the rate at which the SSC200 transmits NMEA 0183 sentences?
Viewed 2328 times since Thu, Jun 19, 2008
Yes, you can change how often the SSC200 transmits messages over the NMEA 0183 network. There are two ways to change the rate at which NMEA 0183 sentences are transmitted: 1) using Maretron's DSM150, DSM200, or DSM250 display, or 2) sending the ... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a DST100 configuration setting called "Trip log:"; what is this?
Viewed 2326 times since Sun, Jun 22, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a DST100 configuration setting called "Trip Log:", which is used to reset the trip log information back to zero. Read More
How do I operate the DSM250 backlights?
Viewed 2317 times since Tue, Sep 1, 2009
The second buttonfrom the left is the back-light button. While in favorite screen mode, do aquick press of the back-light button to step through one of three back-lightintensities. We say a quick press since a long press of the bac... Read More
How do I display the GPS100 sunset time on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2315 times since Tue, Jun 17, 2008
The GPS100 doesn't actually compute and transmit the sunset time over an NMEA 2000 network. However, the DSM200 and DSM250 receive enough information from the GPS100 (time and position) to compute the sunset time. You display the sunset time on ... Read More
How do I display the GPS100 twilight PM time on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2314 times since Tue, Jun 17, 2008
The GPS100 doesn't actually compute and transmit the twilight PM time over an NMEA 2000 network. However, the DSM150, DSM200, and DSM250 receive enough information from the GPS100 (time and position) to compute the twilight PM time. You display ... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Rate of Turn Zero Offset Calibration..."; what is this?
Viewed 2305 times since Sat, Jul 19, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Rate of Turn Zero Offset Calibration...", which is used to calibrate the rate of turn gyro found within the SSC200. Rate gyros tend to drift over temperat... Read More
How do I reset the SSC200 to send the factory default NMEA 0183 sentences?
Viewed 2300 times since Thu, Jun 19, 2008
You reset the SSC200 to transmit the factory default NMEA 0183 messages using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Configuration:" and ... Read More
Can I set the TLA100 to accept the European standard for resistance values (i.e. 10 to 180 ohms) using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2285 times since Thu, Jun 19, 2008
Yes, it is possible to set the TLA100 to accept European standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, sc... Read More
I see that Maretron’s DSM150 and DSM250 displays have a SSC200 configuration setting called "NMEA 2000 PGN Enable/Disable..."; what is this?
Viewed 2281 times since Thu, Jun 19, 2008
Maretron's DSM150 and DSM250 displays have a SSC200 configuration setting called "NMEA 2000 PGN Enable/Disable:", which is used to turn on and off specific NMEA 2000 messages that are transmitted by the SSC200. Read More
Is it possible to turn on or off TLA100 transmitted messages (or PGNs)?
Viewed 2278 times since Fri, Jun 20, 2008
Yes, it is possible to turn on and off the TLA100 transmitted messages (or PGNs) using Maretron's DSM150, DSM200, or DSM250 display:On the display, enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Configuration:" ... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Magnetic Deviation Status?"; what is this?
Viewed 2278 times since Thu, Jun 19, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Magnetic Deviation Status...", which is used to display information about the deviation table that was stored within the compass when the compass was last... Read More
How do I display the GPS100 Speed Over Ground (SOG) using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2256 times since Tue, Jun 17, 2008
You display the GPS100 Speed Over Ground (SOG) information on a DSM150, DSM200, or DSM250 in the following way.Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the SOG... Read More
Can I set the TLA100 to accept the American standard for resistance values (i.e. 240 to 33 ohms) using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2249 times since Fri, Jun 20, 2008
Yes, it is possible to set the TLA100 to accept American standard resistive sensors using Maretron's DSM150, DSM200, or DSM250 display. Set the mode using Maretron's DSM150, DSM200, or DSM250 display in the following way:Enter menu mode, sc... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a GPS100 configuration setting called "NMEA 2000 PGN Enable/Disable..."; what is this?
Viewed 2249 times since Tue, Jun 17, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a GPS100 configuration setting called "NMEA 2000 PGN Enable/Disable:", which is used to turn on and off specific messages that are transmitted by the GPS100. Read More
Why does the SSC200 rate of turn indicate that I am turning when I am not turning?
Viewed 2243 times since Thu, Jun 19, 2008
The SSC200 rate of turn may indicate that the vessel is turning when the vessel is not turning. You correct this situation by calibrating the rate of turn gyro within the SSC200 using either a DSM200 or a DSM250. To calibrate the rate of turn using o... Read More
How do I display the DST100 trip log using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2234 times since Sun, Jun 22, 2008
You display the DST100 trip log information on a DSM150, DSM200, or DSM250 in the following way.Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the trip log and press... Read More
How do I display the SSC200 roll angle on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2230 times since Thu, Jun 19, 2008
You display the SSC200 roll angle on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view roll and press < Enter >Scroll t... Read More
How do I display the GPS100 twilight AM time on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2225 times since Tue, Jun 17, 2008
The GPS100 doesn't actually compute and transmit the twilight AM time over an NMEA 2000 network. However, the DSM150, DSM200, and DSM250 receive enough information from the GPS100 (time and position) to compute the twilight AM time. You display ... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Reset Factory Defaults"; what is this?
Viewed 2214 times since Fri, Jun 20, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Reset Factory Defaults", which is used to return the TLA100 to its factory settings. Resetting the TLA100 resets the tank type back to "Fuel", resets the ... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Levels Calibration..."; what is this?
Viewed 2211 times since Mon, Jun 29, 2009
Maretron's DSM150, DSM200 and DSM250 displays have a TLA100 configuration setting called "Tank Levels Calibration:", which is used to program the type of sensor (American or European standard) that is connected to the TLA100. This setting can al... Read More
How do I reset the TLA100 to send the factory default messages (or PGNs)?
Viewed 2202 times since Fri, Jun 20, 2008
You reset the TLA100 to transmit the factory default messages using Maretron's DSM250 display in the following way:Enter menu mode, scroll to "Configuration:" and press < Enter >Scroll to "Device Configuration:" and press < Enter >Scroll to the ... Read More
How do I create or edit a Favorite screen using the Maretron DSM150, DSM200, or DSM250?
Viewed 2198 times since Sun, Aug 17, 2008
Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would like to set your data info and press enter. Scroll to "Data:" and press enter. Scroll to the data type you wish to display and press ... Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "NMEA 2000 PGN Enable/Disable..."; what is this?
Viewed 2160 times since Fri, Jun 20, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "NMEA 2000 PGN Enable/Disable:", which is used to turn on and off specific messages that are transmitted by the TLA100. Read More
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a WSO100 configuration setting called "Reset Factory Defaults"; what is this?
Viewed 2113 times since Sat, Aug 2, 2008
Maretron's DSM150, DSM200, and DSM250 displays have a WSO100 configuration setting called "Reset Factory Defaults", which is used to return the WSO100 to its factory settings. Resetting the WSO100 clears the installation offset, resets the wind ... Read More
How do I display the SSC200 pitch on Maretron’s DSM150, DSM200, or DSM250?
Viewed 2106 times since Thu, Jun 19, 2008
You display the SSC200 pitch on a DSM150, DSM200, or DSM250 in the following way:Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view pitch and press < Enter >Scroll to "D... Read More
How do I configure a channel on the SIM100 using Maretron’s DSM250 Display?
Viewed 2070 times since Tue, Sep 1, 2009
You configure a channel on the SIM100 in the following way. Enter menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and press enter. Scroll to the row containing SIM100 and press enter. Select instance pr... Read More
How do I display temperature from a TMP100 on the Maretron DSM250 Display?
Viewed 2042 times since Tue, Sep 1, 2009
You display temperature from a TMP100 using the DSM250 in the following way. Enter menu mode (press the enter or far right hand button), scroll to "Favorite Screen Setup…" and press enter. Scroll to the favorite screen where you would like to view th... Read More
Does Maretron offer a Quick Setup guide for the SIM100 using N2KAnalyzer?
Viewed 1995 times since Tue, May 5, 2015
Maretron's Switch Indicator Module monitors dry contacts. Once you have selected the dry contact device, connect the two leads from the device to one of six SIM100 channels.Each channel has two terminals; for example, Channel #0 uses terminals 1... Read More
Which Martron products work with the ALM100?
Viewed 1650 times since Wed, Jun 22, 2016
The ALM100 can be commanded to annunciate by way of Maretron Displays(excluding legacy DSM200) or PC software N2KView(alerts enabled) only. Third-Party devices, Chart-plotters, and MFDs are not compatible to with the ALM100. Read More
Can I use the DCR100 to turn on my Marine Audio Amplifier ?
Viewed 1558 times since Tue, Jul 19, 2016
Yes, The DCR100 can control your audio amplifier by way of the “Remote” input to the amplifier. For vessels with large audio networks an N2KView user can use this feature to selectively control audio amplifiers by way of a single or multiple DCR100 c... Read More
How do I display the J2K100 engine speed or tachometer on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 1432 times since Thu, Jan 14, 2010
You display the J2K100 tachometer on a DSM150, DSM200, or DSM250 in the following way.Enter menu mode, scroll to "Favorite Screen Setup..." and press < Enter >Scroll to the favorite screen where you would like to view the tachometer and press < Enter... Read More
I see that the DCR100 has a configuration feature called Operating Mode, What does this mean?
Viewed 1328 times since Thu, Mar 23, 2017
DCR100 channels have two possible operating modes: “Normal”, in which the DCR100 channel responds to standard NMEA 2000 switching commands, and “Annunciator”, in which the channel may be connected to a power source for a sounder or a light to be acti... Read More
How do I display Tank level on a DSM410?
Viewed 1304 times since Tue, Jul 10, 2018
The DSM250 supports the display of information for up to sixteen tanks types (16 fuel plus 16 water,etc.).Tank sub-categories include:Capacity – displays the fluid capacity of the tankLevel – displays the level of fluid in the tank as a percentage of... Read More
What are the latest changes that have been made to DSM410?
Viewed 1037 times since Wed, May 17, 2017
Revision history for the DSM410 4.1" High Bright Color Display 1.8.1.2(2018-16-10)Disable true power off feature to improve power on sequence 1.7.5.3(2018-01-24):Correctly display invalid data in LAT/LON screen (4405)Correctly display PGN 129029 data... Read More
What firmware changes have taken place on the Maretron DSM410?
Viewed 265 times since Tue, Jul 14, 2020
DSM410 Firmware Versions 1.8.3.2 (2020-08-14)Support TSM810C, TSM1210C, MBB300C configurationFor FFM100 configuration menu, always display K-Factor as 1000 when the K-Factor on FFM100 is 1000. This fix an issue caused after load default to FFM100 and... Read More
|