What firmware changes have taken place on the Maretron DSM410?

What firmware changes have taken place on the Maretron DSM410 display?

Update your device using the N2KAnalyzer software tool.

 

DSM410 Firmware Versions

 

1.8.6.3 (2022-03-16)

  • Fix rolling toad trail issue on VGA resolution display
  • Correct Demo icon position on VGA resolution display
  • Change screen lock mode selection from buttons combination on power up to power down options selections
  • Add testmode command "startup" to support startup options
  • Fix rolling road crash when ellipse cannot be drawn
  • Correct DCM menu display text GEL

 

1.8.5.2 (2021-10-07) - Not Released

  • In power off state, keep internal power supply active if N2K supply voltage is less than 10V

 

1.8.4.6 (2021-04-21)

  • Support Yaw (PGN# 127257)
  • Support Generic Sensor device
  • Support Standard N2K Label (PGN# 130060)
  • Support Shaft Seal Temperature (15) for DD291 (Bug #4702)
  • Fix annunciator stop working after deleting issue (Bug #4652)
  • Add units for Force (Bug #3749)

 

1.8.3.2 (2020-08-14)

  • Support TSM810C, TSM1210C, MBB300C configuration
  • For FFM100 configuration menu, always display K-Factor as 1000 when the K-Factor on FFM100 is 1000. This fix an issue caused after load default to FFM100 and the DSM display the old K-Factor value before loading default, this issue also fixed in the FFM100 SW 1.4.1.1
  • Support CLM100 SW 1.2+
  • Support CLM100 configuration for Battery, Engine, Transmission, and Vessel Devices

 

1.8.1.2 (2018-10-15)

  • Initial customer release
Attachments Attachments
There are no attachments for this article.
Related Articles RSS Feed
How do I reset the J2K100 to send the factory default NMEA 2000 messages (or PGNs)?
Viewed 3195 times since Thu, Jan 14, 2010
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a SSC200 configuration setting called "Variation Source:"; what is this?
Viewed 2811 times since Thu, Jun 19, 2008
I have configured my DSM410 or DSM250; how do I perform a backup?
Viewed 5539 times since Tue, Feb 26, 2013
How do I make the SSC200 agree with other compasses on the vessel, or, in other words, how do I align the SSC200 with the boat?
Viewed 2823 times since Mon, Jun 25, 2012
How do I display the GPS100 moon phase on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2924 times since Tue, Jun 17, 2008
How do I clear the WSO100 outside temperature offset using Maretron’s DSM150 or DSM250 display?
Viewed 2889 times since Mon, Jun 25, 2012
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a WSO100 configuration setting called "Reset Factory Defaults"; what is this?
Viewed 2432 times since Sat, Aug 2, 2008
How do I reset the GPS100 to send the factory default NMEA 2000 messages (or PGNs)?
Viewed 2931 times since Tue, Jun 17, 2008
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called "NMEA 2000 PGN Enable/Disable..."; what is this?
Viewed 3094 times since Thu, Jan 14, 2010
I see that the FPM100 has an accessory for measuring pressures in the range of -1Bar to 1 Bar. Can I use this sensor to monitor my fuel filters?
Viewed 3070 times since Thu, Dec 18, 2014
Subscribe to knowledgebase
Get notified when new articles are added to the knowledgebase.