Knowledge Base
Home » Categories » Navigation Instruments » WSO100 (Discontinued)

What messages (or PGNs) does the WSO100 transmit?

The WSO100 transmits the following messages (or PGNs):

  • PGN 130306 - Wind Data (Fields: 1-SID, 2-Wind Speed, 3-Wind Direction, 4-Wind Reference)
  • PGN 130310 - Environmental Parameters (Fields: 1-SID, 2-Water Temp, 3-Outside Ambient Air Temperature, 4-Atmospheric Pressure)
  • PGN 130311 - Environmental Parameters (Fields: 1-SID, 2-Water Temperature, 3-Outside Ambient Air Temperature, 4-Atmospheric Pressure)
  • PGN 130312 - Temperature (Fields: 1-SID, 2-Temperature Instance, 3-Temperature Source, 4-Actual Temperature, 5-Set Temperature)
  • PGN 130313 - Humidity (Fields: 1-SID, 2-Humidity Instance, 3-Humidity Source, 4-Actual Humidity, 5-Set Humidity)
  • PGN 130314 - Actual Pressure¬†(Fields: 1-SID, 2-Pressure Instance, 3-Pressure Source, 4-Actual Pressure, 5-Set Pressure)
Attachments Attachments
There are no attachments for this article.
Related Articles RSS Feed
I see that Maretron’s DSM200 and DSM250 displays have a WSO100 configuration setting called "Wind Data Damping Period:"; what is this?
Viewed 2333 times since Wed, Jun 25, 2008
How do I clear the WSO100 atmospheric pressure offset using Maretron’s DSM150 or DSM250 display?
Viewed 2971 times since Sat, Aug 2, 2008
How do I display the WSO100 barometric pressure on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2760 times since Thu, Jul 10, 2008
How do I display the WSO100 true wind referenced to ground speed on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2932 times since Sun, Jan 30, 2011
How do I display the WSO100 true wind referenced to water speed on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3012 times since Sun, Jan 30, 2011
Why doesn’t the WSO100 atmospheric pressure agree with my locally reported barometric pressure?
Viewed 2778 times since Wed, Jun 25, 2008
Using N2KAnalyzer, how do I recover a Maretron device?
Viewed 2629 times since Thu, Dec 22, 2011
What components does Maretron recommend in order to view environmental information at the top of a mast?
Viewed 2955 times since Fri, Jul 24, 2009
How do I set the WSO100 outside humidity offset using Maretron’s DSM150 or DSM250 display?
Viewed 1903 times since Wed, Jun 25, 2008
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a WSO100 configuration setting called "NMEA 2000 PGN Enable/Disable..."; what is this?
Viewed 2065 times since Wed, Jun 25, 2008
Subscribe to knowledgebase