Does Maretron offer a Quick Setup guide for the SIM100 using N2KAnalyzer?

Maretron's Switch Indicator Module monitors dry contacts. Once you have selected the dry contact device, connect the two leads from the device to one of six SIM100 channels.

Each channel has two terminals; for example, Channel #0 uses terminals 1 and 2(illustrated below), while Channel#6, uses terminals 11 and 12.

You can set up this device by using one of Maretron's configuration tools such as DSM150 and DSM250 displays or N2KAnalyzer software (N2KAnalyzer requires a IPG100 or USB100 gateway). This article will discuss using the N2KAnalyzer for hardware configuration.

After you have installed the switch closure devices and connected them to the SIM100,  you will want to begin configuring the SIM100 output messaging for Maretron system displays. Details on the display of SIM100 messages can be found within Maretron DSM250 User's Manual section "Indicators". For N2KView applications, please review the following link: https://www.maretron.com/support/knowledgebase/phpkbv7/article.php?id=615

 

Due to the complexity of systems with multiple devices that will transmit switch status 127501. Maretron recommends that a label is stored to the device channel for ease of displaying the intended value.

For systems that will have 2 or more Maretron SIM100, RIM100, DCR100. take advantage of the instancing analysis tool to identify instancing conflicts.

First select the SIM100 in the N2KAnalyzer, followed by selecting menu item Configuration-->Device Configuration.
(next steps refer to Figure 1)

1. Set the device label, this label will show on the DSM250 or N2KView when choosing a switch bank instance. As seen in Figure#1 this SIM100 is assigned to monitor the vessels smoke detectors.

2. Set the Instance number that will not conflict with another switch device.

3.  Set the mode for channels 1-6 and assign each channel a label as well. The label will be visible during favorite screen setup on your Maretron displays.

4. "Put Config to Device" finalizes your setup and you are ready to move on.

 

Here is a sample of an N2KView component pointed to a SIM100  on the NMEA2000 network monitoring Bilge High Water condition:

 

 

 

Attachments Attachments
There are no attachments for this article.
Related Articles RSS Feed
Why can’t I find a particular TLA100 tank level for display on Maretron’s DSM150, DSM200, or DSM250?
Viewed 3206 times since Fri, Jun 20, 2008
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Levels Calibration..."; what is this?
Viewed 2765 times since Mon, Jun 29, 2009
What sensors does Maretron recommend for basic navigation?
Viewed 4396 times since Wed, Apr 10, 2013
Can I set the RAA100 to accept the American standard for resistance values (i.e. 240 to 33 ohms) using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3300 times since Fri, Jul 11, 2008
What information is available from the temperature monitor (TMP100) and can be viewed on Maretron’s displays?
Viewed 4549 times since Fri, Jun 21, 2013
How do I calibrate the SSC200 rate of turn using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2850 times since Thu, Jun 19, 2008
How do I display the J2K100 engine hours on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 4458 times since Thu, Jan 14, 2010
How do I know if the GPS100 is locked on and producing a position fix using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 3549 times since Tue, Jun 17, 2008
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a GPS100 configuration setting called "Reset Factory Defaults"; what is this?
Viewed 2981 times since Thu, Mar 5, 2009
Can I use the SIM100 to tell whether a bulb is burnt out?
Viewed 4286 times since Thu, Sep 2, 2010
Subscribe to knowledgebase
Get notified when new articles are added to the knowledgebase.