What marine engines are found to have J1939 capability?

Following is a table showing engines and their J1939 capability. 

 Engine manufacturer   Controller Module  J1939 Capable standard? Must Be Ordered With J1939 Capabilities.
 Caterpillar    ADEM III and A4/C4.4, C6.6, C9, C15, C18, C32   "Acerts series"  Yes: J1939 Tx  
 Cummins     CM570 and CM850/QSL, QSB5 and 7, QSM11, QSK19,50 and 60   Yes: J1939 Tx  
 Detroit Diesel  DDEC III and IV/Series 50, 60 and 2000 Rx  Yes: J1939 Tx  
 Deutz  EMR 2 (EMR)/912, 913, 914 and L2011  Yes: J1939 Tx  
 Iveco EDC7  (Bosch MS6.2)/Series NEF, CURSOR and VECTOR 8  Yes: J1939 Tx  
 John Deere  JDEC/PowerTech M, E and Plus  Yes: J1939 Tx  
 MAN  MMDS series  Yes: J1939 Tx  
 MTU MDEC  module M.302 or M.303/Series 2000 and 4000  NO: J1939 Tx Yes
 MTU MDEC   module M.201 or M.304/Series 2000 and 4000 Rx  NO: J1939 Tx Yes
 MTU  ADEC/Series 2000 and 4000  NO: J1939 Tx Yes
 Perkins  Series 1100, 1300, 2300 and 2800  Yes: J1939 Tx  
 Scania  EMS  Yes: J1939 Tx  
 Scania   EMS S6 (KWP2000)/Dx9x, Dx12x, D13x, Dx16x   Yes: J1939 Tx  
 Steyr Motors  M1-CU, 4/6 cylinder Solas    
 Volvo Penta  EDC4, EMS,  EMS 2, EDCIII/D6, D7, D9, D12 and D16, EVC models, EDC (GE and AUX variants only)  Yes: J1939 Tx  
 Yanmar  BY2 series, LY-series  Yes: J1939 Tx  
 Crusader  MPI series ECM-07  Yes: J1939 Tx  

 What should I look for when considering the J2K100 gateway/bridge?

Technicians can look for an engines diagnostic connection in close proximity to an engine ECU. Generally, most diagnostic connectors used by the engine manufacturers are standard and manufactured by Deutsch connector company. Under article attachments, Maretron provides a printable cheat sheet to help technicians identify engine J1939 connections and the engine connectors known pin designations. Note: take caution when tampering with Engine ECUs, always refer to the engines service manual and or consult the engine manufacturer for the correct connection to use for the J2K100.  

 

Attachments (1) Attachments
Related Articles RSS Feed
Why doesn’t the J2K100 work with some versions of Onan generators?
Viewed 2185 times since Thu, Jan 14, 2010
How do I display the J2K100 engine speed or tachometer on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 938 times since Thu, Jan 14, 2010
How do I display the J2K100 engine fuel rate on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2781 times since Thu, Jan 14, 2010
What is a J2K100?
Viewed 2622 times since Thu, Jan 14, 2010
I know the J2K100 receives messages from the J1939 network and subsequently transmits them over the NMEA 2000 network, but does the J2K100 transmit any messages on the J1939 network?
Viewed 2094 times since Thu, Jan 14, 2010
How do I display the J2K100 generator average AC current on Maretron’s DSM150 or DSM250 display?
Viewed 2231 times since Thu, Jan 14, 2010
If I use the J2K100 with my Onan generator that has a power rating between 40-99kW, what data can I expect to see on the NMEA 2000 network?
Viewed 2127 times since Thu, Jan 14, 2010
How do I display the J2K100 engine oil temperature on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2556 times since Thu, Jan 14, 2010
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called "NMEA 2000 Engine Instance:"; what is this?
Viewed 1929 times since Thu, Jan 14, 2010
I would like to see NMEA2000 Engine and Transmission warnings on my N2K network, what J1939 diagnostic codes will the J2K100 convert?
Viewed 3788 times since Fri, Oct 16, 2015
Subscribe to knowledgebase
Get notified when new articles are added to the knowledgebase.