Knowledge Base
Home » Categories » User Interface Hardware » DSM250 » Configuring the DSM250

Does Maretron offer a quick setup procedure for a DSM250 Anchor Watch favorite screen?

DSM150 and DSM250 display with firmware version 1.4.6 or higher with factory default settings have a single anchor watch alert and favorite screen associated.

  • Favorite screen 12 has the Anchor watch displayed.  
  • The Anchor radius defaults to 100 Feet.
  1. Use the arrow keys to display favorite screen 12 with the Anchor watch display.
  2. Press the < Enter > key to display the menu
  3. Press < Enter > to display the Alert menu and then use the arrow keys to scroll to the "Edit Alert..." submenu
  4. Press < Enter > to display the Edit Alert submenu. The Anchor Watch alert will be highlighted.
  5. "Enable/Disable Control" will be highlighted. Press < Enter > to highlight "Disable", press the < Up > or < Down > keys to change it to read "Enable" and press < Enter > once more.
  6.  Use the < Up > and < Down > keys to move the highlight to "Get Current Position" and press < Enter >.
  7. Use the  < Up > and  < Down > keys to move the highlight to "Operating_Mode_Anchored". Press < Enter > to move the highlight to the right, and then use the < Up > and  < Down > keys to change the field to read "Enable". Then press < Enter >.
  8. Press the < Back > key until the Anchor Watch favorites screen is displayed.
  9. In this screenshot, notice the vessel image drifting outside of the Anchor fence radius prior to an alarm.
  10. Here, the vessel has drifted outside of the Anchor Watch fence. A red arrow indicates the direction of vessel in reference to the Anchor set point.
  11. When an Alert condition is active press the < Power > button       to accept the alert. However, if an alert condition is not cleared, the alarm will remain visible on the upper right corner of the DSM150 or DSM250 display.
Attachments Attachments
There are no attachments for this article.
Related Articles RSS Feed
How do I operate the DSM250 power button?
Viewed 2026 times since Tue, Sep 1, 2009
What are the operating modes of the DSM250?
Viewed 2283 times since Tue, Oct 6, 2009
How do I display temperature from a TMP100 on the Maretron DSM250 Display?
Viewed 1604 times since Tue, Sep 1, 2009
How do I transfer display settings from one DSM150 or DSM250 to another DSM150 or DSM250 on the same NMEA 2000 network?
Viewed 1621 times since Wed, Apr 28, 2010
How do I display Tank level on a DSM410?
Viewed 687 times since Tue, Jul 10, 2018
How do I operate the DSM250 backlights?
Viewed 2047 times since Tue, Sep 1, 2009
Subscribe to knowledgebase
Get notified when new articles are added to the knowledgebase.