Is it possible to wire a manual override switch around the DCR100?

Yes, you can use a manual switch to override the DCR100. Please see the attached diagrams which shows three different circuit configurations.

 

The first circuit diagram shows how the DCR100 is wired into a circuit without any type of manual override. With this configuration, the light is controlled by the Solid State Relay (SSR) within Maretron's DCR100. The light is switched on through NMEA 2000 commands coming from Maretron's dedicated display (DSM150 or DSM250) or Maretron's vessel monitoring and control software (N2KView). One issue with this configuration has to do with removal of NMEA 2000 power from the DCR100, which causes the SSRs within the DCR100 to turn off. Please refer to the second and third diagrams for getting around the problem where NMEA 2000 power is removed from the DCR100 and all channels turn off.

 

 

The second diagram shows a Single Pole, Single Throw (SPST) switch added to the circuit. This switch allows the lamp to be manually turned on and off if the NMEA 2000 power is removed from the DCR100. This circuit configuration overcomes the issue associated with lost NMEA 2000 power, but it doesn't address all failure modes of the DCR100, namely a short circuited SSR within the DCR100. If an SSR within the DCR100 becomes short circuited, then the load cannot be turned off. Please refer to the third diagram for getting around the problem where an SSR within the DCR100 is short circuited.

 

 

 

 

The third diagram shows a Double Pole, Triple Throw (DP3T) switch added to the circuit. This switch allows the DCR100 to work in its normal mode under control of the NMEA 2000 network (Auto or center position), or the switch can be used as a manual override (On or Off positions) completely independent of the DCR100.

 

 

 

Under normal circumstances, the first circuit diagram is all that is required. If you want to be able to shut down the NMEA 2000 network but still have manual turn On and Off capability, then the second diagram should be adequate. For systems where it is imperative to be able to turn On and Off a circuit under all conditions (i.e., failed NMEA 2000 network and/or failed DCR100), then the third circuit diagram should be the choice.

 

Attachments Attachments
There are no attachments for this article.
Related Articles RSS Feed
What firmware changes have taken place on the Maretron DCR100?
Viewed 2291 times since Fri, Jul 19, 2013
What is a DCR100?
Viewed 2207 times since Sat, Apr 30, 2011
How do I show simple bilge information on Mareton’s DSM150 or DSM250 displays?
Viewed 3249 times since Sat, Apr 27, 2013
The DCR100 will not allow me to switch on/off a relay channel. Why?
Viewed 1934 times since Thu, Sep 13, 2012
What are the voltage specifications for each Maretron device?
Viewed 4978 times since Thu, Dec 22, 2011
Can Non-Maretron displays control the DCR100?
Viewed 1321 times since Mon, Jul 13, 2015
Using N2KAnalyzer, how do I recover a Maretron device?
Viewed 2073 times since Thu, Dec 22, 2011
I see N2KView offers a component for "Indicator Status"; what products can I use to show Indicator Status?
Viewed 1987 times since Fri, Mar 27, 2015
Can I turn On and Off loads connected to the DCR100 using the DSM150 or DSM250?
Viewed 2498 times since Thu, May 5, 2011
Can I use the DCR100 to switch AC loads?
Viewed 2617 times since Mon, May 21, 2012
Subscribe to knowledgebase
Get notified when new articles are added to the knowledgebase.