What firmware changes have taken place on the Maretron USB100?

USB100 Firmware Versions:

USB100 1.9.1.1 (2018-01-24):
USB100 2.1.1.2:
Added support for the latest NMEA2000 PGN (211)
Added support for the NMEA 2000 Heartbeat Message (PGN 126993) (4435)


 2.0.3.1(08-2016):

  • Changed supported NMEA 2000 database version to 2.1 (2634)
  • Corrected a problem where the USB100 does not transmit the RMB sentence when it is configured to do so (3824)
  • Pass along ACK/NACK messages to application (2600)

Hardware 1.0

Version 1.8.6.2 (03-2015)

 

-      Added support for translation of J1939/NMEA 2000 Generator Total AC Energy PGN 65018, Generator Total AC Reactive Power PGN 65028, Generator Total AC Power PGN 65029, and Generator Average Basic AC Quantities PGN 65030 from a single generator to NMEA 0183 (3303)

 

-      Added support for translation of NMEA 2000 Trip Parameters, Engine PGN 127497 to new NMEA 0183 “ETP” proprietary sentence (3306)

 

-      Added support for translation of NMEA 2000 temperature PGNs 130316 and 130312 to NMEA 0183 and added support for multiple temperature sources (3304)

 

-      Added support for translation of NMEA 2000 pressure PGN 130314 to NMEA 0183 (3305)

 

-      Added support for translation of NMEA 2000 humidity PGN 130313 to NMEA 0183 (3376)

 

 

Hardware 2.0

 

2.0.2.2 (03-2015)

 

-      Made more robust in case USB connection was interrupted by external fast transients (3374)

 

-      Added support for translation of J1939/NMEA 2000 Generator Total AC Energy PGN 65018, Generator Total AC Reactive Power PGN 65028, Generator Total AC Power PGN 65029, and Generator Average Basic AC Quantities PGN 65030 from a single generator (3303)

 

-      Added support for translation of NMEA 2000 Trip Parameters, Engine PGN 127497 to new NMEA 0183 “ETP” proprietary sentence (3306)

 

-      Added support for translation of NMEA 2000 temperature PGNs 130316 and 130312 to NMEA 0183 and added support for multiple temperature sources (3304)

 

-      Added support for translation of NMEA 2000 pressure PGN 130314 to NMEA 0183 (3305)

 

-      Added support for translation of NMEA 2000 humidity PGN 130313 to NMEA 0183 (3376)

 

 

 

1.8.3 (2009-03-20)

- Added translation for 130576 (Small Craft Status) to NMEA 0183 XDR sentence for trim tabs

 

1.8.2 (2008-03-10)

- Reduced network load when searching for devices on powerup

 

1.8.1 (2008-03-03)

- Fixed problem where the device tried to transmit a PGN before it had acquired a node address

- Increased the number of devices that are supported in the Device Selection menu from 50 to 256

 

1.7.2 (2007-10-16)

- Added PGN 126996 to received PGN list  in NMEA0183 mode

- Add support for single frame proprietary (Global) PGN 65280-65535 and fast packet proprietary (Global) PGN 130816-131071

 

1.7.1 (2007-07-09)

- Added support for draft NMEA 2000 intelligent gateway specification

- Added support to keep connection to the USB port if NMEA 2000 power is interrupted

- Added notification to the connected computer when the NMEA 2000 power is lost

- Changed to always restart in NMEA 0183 mode on power-up (rather than previous mode)

- Add ability to respond to USB node reset command

 

1.6.5 (2006-11-09)

- Added translations for fluid level and engine messages

 

USB100 SW 1.6.4 (2005-09-20)

- Added support for USB 2.0 hubs

- Updated supported version of the NMEA 2000 protocol to 1.200

 

1.6.3 (2005-07-22)

- Added support for Environmental PGN 130311

 

1.6.2 (2005-06-23)

- Changed NMEA 2000 protocol behavior

 

1.5 (2005-02-10)

- Made improvements in remote device selection copying

 

1.4 (2005-02-09)

- Removed some translations to free up space in program memory

 

1.3 (2005-02-07)

- Changed NMEA 2000 protocol behavior

 

1.2 (2005-02-04)

- Initial public release

 

 

USB100 Hardware Revision 1 (Version 1.8.6.2):

-      Added support for translation of J1939/NMEA 2000 Generator Total AC Energy PGN 65018, Generator Total AC Reactive Power PGN 65028, Generator Total AC Power PGN 65029, and Generator Average Basic AC Quantities PGN 65030 from a single generator to NMEA 0183 (3303)

-      Added support for translation of NMEA 2000 Trip Parameters, Engine PGN 127497 to new NMEA 0183 “ETP” proprietary sentence (3306)

-      Added support for translation of NMEA 2000 temperature PGNs 130316 and 130312 to NMEA 0183 and added support for multiple temperature sources (3304)

-      Added support for translation of NMEA 2000 pressure PGN 130314 to NMEA 0183 (3305)

-      Added support for translation of NMEA 2000 humidity PGN 130313 to NMEA 0183 (3376)

 

USB100 Hardware Revision 2 (Version 2.0.2.2):

-      Made more robust in case USB connection was interrupted by external fast transients (3374)

-      Added support for translation of J1939/NMEA 2000 Generator Total AC Energy PGN 65018, Generator Total AC Reactive Power PGN 65028, Generator Total AC Power PGN 65029, and Generator Average Basic AC Quantities PGN 65030 from a single generator (3303)

-      Added support for translation of NMEA 2000 Trip Parameters, Engine PGN 127497 to new NMEA 0183 “ETP” proprietary sentence (3306)

-      Added support for translation of NMEA 2000 temperature PGNs 130316 and 130312 to NMEA 0183 and added support for multiple temperature sources (3304)

-      Added support for translation of NMEA 2000 pressure PGN 130314 to NMEA 0183 (3305)

-      Added support for translation of NMEA 2000 humidity PGN 130313 to NMEA 0183 (3376)

 

 

Attachments Attachments
There are no attachments for this article.
Related Articles RSS Feed
What is GWUtilities used for?
Viewed 1929 times since Fri, Jun 26, 2015
What are the voltage specifications for each Maretron device?
Viewed 7574 times since Thu, Dec 22, 2011
Using N2KAnalyzer, how do I recover a Maretron device?
Viewed 4592 times since Thu, Dec 22, 2011
What type of information can be viewed on Maretron’s display products, and what products are required to generate the data to be displayed?
Viewed 24629 times since Tue, Oct 25, 2011
How can I tell which messages (PGNs) are being sent on the J1939 bus by an engine or genset?
Viewed 3298 times since Thu, Jun 23, 2011
Does the USB100 convert NMEA 2000 engine PGNs to NMEA 0183 sentences?
Viewed 6041 times since Mon, Jan 18, 2010
GWUtilities and USB100 drivers
Viewed 3994 times since Mon, May 16, 2011
Using GWUtilities, what mesages can I configure?
Viewed 4623 times since Fri, Jun 26, 2015