Knowledge Base
Home » Categories » Multiple Categories

How do I configure an EMS100 that is connected to a Yanmar engine?

NOTE: The EMS100 has been discontinued and is no longer offered for sale.

To configure the EMS100 using the DSM250, start from the favorite screen mode and press the enter key or the far right hand button, scroll to configuration and press enter, scroll to device configuration and press enter,  scroll to the EMS100 and press enter, scroll to "Engine Instance:" and press enter. If you are configuring a single engine or the port engine in a twin engine configuration then use the up arrow to select instance #0, if you are configuring the starboard engine then choose instance #1. Press enter to save the instance selection or press back to cancel the selection. Next, scroll to the "Label:" entry and press enter, you will be taken to a special screen that will allow you to enter a descriptive label instead of referring to a cryptic instance number. Once you are satisfied with the label, choose "Save & Exit". Next, you will need to configure the Boost Pressure, Drive Trim, Oil Pressure, Water Temperature. Each of these parameter allows you to configure "Gauge Type" and "Sender Type". For the "Gauge Type", you can choose either "No Gauge", or "Yanmar", or "Yanmar/VDO" depending on the type of gauge installed in the Yanmar instrument panel. Please consult the Yanmar instrument panel documentation for determining what type of gauges are installed. For the "Sender Type", you can choose "Disable" if that particular sender isn't installed, or you can choose "Yanmar" or "VDO". Please consult the Yanmar engine documentation for determining what type of gauges are installed. Next, scroll to "Preset Engine Hours" and enter the appropriate engine hours. The EMS100 will report the engine hours, plus it will totalize all future engine time any time the key is switched on. Lastly, scroll to "Tach. Flywheel Teeth". This is where you configure the EMS100 to properly calculate RPM. Either consult the Yanmar engine documentation or look at the tachometer gauge for a small number printed at the bottom of the gauge to determine the number to use for this configuration.


Attachments Attachments
There are no attachments for this article.
Related Articles RSS Feed
Which Maretron products are necessary in order to display apparent wind?
Viewed 3249 times since Wed, Apr 10, 2013
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Operating Mode:"; what is this?
Viewed 2036 times since Thu, Jun 19, 2008
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a WSO100 configuration setting called "Reset Factory Defaults"; what is this?
Viewed 1801 times since Sat, Aug 2, 2008
How do I reset the J2K100 to send the factory default NMEA 2000 messages (or PGNs)?
Viewed 2350 times since Thu, Jan 14, 2010
What are the basic configurable parameters for the TLM100 and how do I configure them using a DSM250?
Viewed 3280 times since Wed, Oct 7, 2009
How do I set the TLA100 operating mode using Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2201 times since Fri, Jun 20, 2008
How do I reset the TLA100 to send the factory default messages (or PGNs)?
Viewed 1816 times since Fri, Jun 20, 2008
How do I display the J2K100 generator average AC current on Maretron’s DSM150 or DSM250 display?
Viewed 2267 times since Thu, Jan 14, 2010
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a GPS100 configuration setting called "Cold Start GPS Engine"; what is this?
Viewed 2136 times since Tue, Jun 17, 2008
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a J2K100 configuration setting called "NMEA 2000 PGN Enable/Disable..."; what is this?
Viewed 2243 times since Thu, Jan 14, 2010
Subscribe to knowledgebase
Get notified when new articles are added to the knowledgebase.