How do I calibrate the SSC200 rate of turn using Maretron’s DSM150, DSM200, or DSM250 display?

You calibrate the SSC200 rate of turn using a DSM150, DSM200, or DSM250. To calibrate the rate of turn using one of the displays:

  1. Enter menu mode, scroll to "Configuration..." and press < Enter >
  2. Scroll to "Device Configuration..." and press < Enter >
  3. Scroll to the SSC200 and press < Enter >
  4. Scroll to "Rate of Turn Zero Offset Calibration..." and press < Enter >
  5. Follow the instructions on the screen to complete the calibration

If you do this calibration at a couple of temperatures (early in the morning right after you power the compass and again at the hottest part of the day), the SSC200 will provide accurate rate of turn indications across that temperature range.

Attachments Attachments
There are no attachments for this article.
Related Articles RSS Feed
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Capacity:"; what is this?
Viewed 2148 times since Thu, Jun 19, 2008
Is it possible to turn on or off TLA100 transmitted messages (or PGNs)?
Viewed 1936 times since Fri, Jun 20, 2008
Why does the heading coming from the SSC200 appear to be in error?
Viewed 2361 times since Thu, Jun 19, 2008
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Reset Factory Defaults"; what is this?
Viewed 1909 times since Fri, Jun 20, 2008
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Levels Calibration..."; what is this?
Viewed 1888 times since Mon, Jun 29, 2009
I see that Maretron’s DSM150, DSM200, and DSM250 displays have a TLA100 configuration setting called "Tank Number:"; what is this?
Viewed 2384 times since Thu, Jun 19, 2008
I navigate using magnetic heading and not true heading; how do I use the SSC200 compass and Maretron’s DSM150, DSM200, or DSM250 display to view my heading in magnetic?
Viewed 2709 times since Thu, Jun 19, 2008
How do I display the J2K100 engine hours on Maretron’s DSM150, DSM200, or DSM250 display?
Viewed 2622 times since Thu, Jan 14, 2010
I see that Maretron’s DSM150 and DSM250 displays have a SSC200 configuration setting called "NMEA 2000 PGN Enable/Disable..."; what is this?
Viewed 1995 times since Thu, Jun 19, 2008
What is the SMS100 Status message? Which Maretron components do I need?
Viewed 3303 times since Thu, Jun 6, 2013
Subscribe to knowledgebase
Get notified when new articles are added to the knowledgebase.