  1. Using the N2KAnalyzer how do I recover a device?Using the N2KAnalyzer how do I recover a device?
    The N2KAnalyzer software can restore a devices software using the following method: Select the affected device(represented by a row with light gray serial number shown), right-click ...

  2. What are the Voltage specifications for each Maretron device?What are the Voltage specifications for each Maretron device?
    Maretron Model Device Description NMEA2000 Operating Voltage Engine/Battery Interface SSC200 NMEA 2000 Solid State Compass HW 1.0 9 t...

  3. How do I configure a channel on the TMP100 using Maretron's DSM250?How do I configure a channel on the TMP100 using Maretron's DSM250?
    You configure a channel on the TMP100 in the following way. Enter main menu mode, scroll to "Configuration?" and press enter. Scroll to "Device Configuration?" and press enter. Scroll to the row co...

  4. What firmware changes have taken place on the Maretron DSM250?What firmware changes have taken place on the Maretron DSM250?
    Update your device today using the N2KAnalyzer software tool. DSM250 firmware versions 1.4.13.4(2011-10-24) o Adds support for enabling/disabling Maretron C...

  5.  What Maretron devices can one configure with the DSM200 display? What Maretron devices can one configure with the DSM200 display?
    DSM200 was designed and released for sale into the marine market in 2004. It was designed to support Maretron’s envisioned product line at that time. In the years following 2004 Maretron ...

  6. What firmware changes have taken place on the Maretron TMP100?What firmware changes have taken place on the Maretron TMP100?
    What firmware changes have taken place on the Maretron TMP100? TMP100 Firmware Versions: 1.1.1 (2009-02-23) - Added support for labeling so that the device can easily be identified wi...

  7. Can I install a Maretron TMP100 EGT accessory probe downstream of the water cooled exhaust riser or elbow?Can I install a Maretron TMP100 EGT accessory probe downstream of the water cooled exhaust riser or elbow?
    No, Maretron’s EGT sensor is meant to measure the temperature of the exhaust gas temperature, not the temperature of the exhaust gas after it has been cooled by water. Placing the EGT...

  8. What are the dimensions of the Exhaust Gas Temperature (EGT) accessory probe (Maretron part number TP-EGT-1) used with the TMP100?What are the dimensions of the Exhaust Gas Temperature (EGT) accessory probe (Maretron part number TP-EGT-1) used with the TMP100?
    Please see the attached pdf file for the dimension of the EGT probe.

  9. What type of information can be viewed on Maretron's display products, and what products are required to generate the data to be displayed?What type of information can be viewed on Maretron's display products, and what products are required to generate the data to be displayed?
    To get an understanding of what parameters Maretron's displays are capable of showing, and what equipment is necessary for generating the displayed data, please see the attached file, which is entitle...

  10. What are the weights and dimensions of Maretron products?What are the weights and dimensions of Maretron products?


  11. What type of solderless connector is ideal for mating sensor wire to Maretron multi-channel products?What type of solderless connector is ideal for mating sensor wire to Maretron multi-channel products?
    A #4 Nylon Double-Crimp Insulated Ring Terminal( P/N:WT-651045) is the ideal choice when connecting sensor wire to any of Maretron's multi-channel devices. The following link provides a great...