  1. Using the N2KAnalyzer how do I recover a device?Using the N2KAnalyzer how do I recover a device?
    The N2KAnalyzer software can restore a devices software using the following method: Select the affected device(represented by a row with light gray serial number shown), right-click ...

  2. What are the Voltage specifications for each Maretron device?What are the Voltage specifications for each Maretron device?
    Maretron Model Device Description NMEA2000 Operating Voltage Engine/Battery Interface SSC200 NMEA 2000 Solid State Compass HW 1.0 9 t...

  3. How do I display a SIM100 channel on the Maretron DSM250?How do I display a SIM100 channel on the Maretron DSM250?
    You display a SIM100 channel using the DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup…" and press enter. Scroll to the favorite screen where you would like to v...

  4. What firmware changes have taken place on the Maretron DSM250?What firmware changes have taken place on the Maretron DSM250?
    Update your device today using the N2KAnalyzer software tool. DSM250 firmware versions 1.4.13.4(2011-10-24) o Adds support for enabling/disabling Maretron C...

  5.  What Maretron devices can one configure with the DSM200 display? What Maretron devices can one configure with the DSM200 display?
    DSM200 was designed and released for sale into the marine market in 2004. It was designed to support Maretron’s envisioned product line at that time. In the years following 2004 Maretron ...

  6. What PGN's does the SIM100 transmit?What PGN's does the SIM100 transmit?
    The SIM100 will transmit PGN 127501 Field 1SID, 2-28, Switch status.

  7. What is the purpose of the Switch Indicator Module (SIM100)?What is the purpose of the Switch Indicator Module (SIM100)?
    The purpose of the SIM100 is to indicate the state of up to 6 switches over an NMEA 2000 network. THE SIM100 can monitor normally closed switches like magnetic door, window, and hatch ...

  8. What is the SIM100?What is the SIM100?
    The SIM100 continually monitors switch closure devices and broadcasts information over the NMEA 2000 network about the switch state

  9. How many channels are available on the SIM100?How many channels are available on the SIM100?
    The SIM100 has six available channels for use with two types of switches. Please refer to to the SIM100 manual for specifications on these two types of switches.

  10. What firmware changes have taken place on the Maretron SIM100?What firmware changes have taken place on the Maretron SIM100?
    What firmware changes have taken place on the Maretron SIM100? SIM100 Firmware Versions 1.1.1 (2009-02-23) - Updated labeling support 1.0.2 (2008-10-21) - Added sup...

  11. How do I mount the Bilge High Water (BHW100) sensor?How do I mount the Bilge High Water (BHW100) sensor?
    The BHW100 sensor has a target molded into the plastic enclosure (opposite the side with the Maretron label). The target should be exposed so that when the water rises above the middle of ...

  12. Can I use the SIM100 to tell if a bulb is burnt out?Can I use the SIM100 to tell if a bulb is burnt out?
    Yes, you can use the SIM100 together with a CR Magnetics current sensing relay to indicate that a bulb is burnt out. There are many different available configurations of the current sensing ...

  13. Can I use the SIM100 to monitor Carbon Monoxide (CO) detectors?Can I use the SIM100 to monitor Carbon Monoxide (CO) detectors?
    Yes, you can use the SIM100 to monitor Carbon Monoxide (CO) detectors as long as the detector has an auxiliary contact. Some examples of CO detectors with auxiliary contacts are the Fireboy-Xintex (CM...

  14. Can I use the SIM100 to monitor combustible gas detectors?Can I use the SIM100 to monitor combustible gas detectors?
    Yes, you can use the SIM100 to monitor combustible gas detectors as long as the detector has an auxiliary contact. An example of a combustible gas detector with auxiliary contacts is the Macurco GD-1....

  15. I see that some of Maretron’s SIM100 accessories have built in “trouble relays”, what is a trouble relay and why is it important?I see that some of Maretron’s SIM100 accessories have built in “trouble relays”, what is a trouble relay and why is it important?
    Trouble relays are being integrated into more and more safety and security equipment to provide added safety and security features. For example, a trouble relay can act as power ...

  16. Does the gas detector (Maretron part LP-200012UL) have a power supervision relay?Does the gas detector (Maretron part LP-200012UL) have a power supervision relay?
    Although some of Maretron's SIM100 accessories have built in power supervision relays like the smoke/heat detector (Maretron part number SH-449CSTE) and carbon monoxide detector (Maretron ...

  17. What are the dimensions of the SIM100 accessory magnetic sensors?What are the dimensions of the SIM100 accessory magnetic sensors?
    Please see the attached data sheets for the magnetic sensor dimensions. Place your cursor over each image to see the model type.

  18. What type of information can be viewed on Maretron's display products, and what products are required to generate the data to be displayed?What type of information can be viewed on Maretron's display products, and what products are required to generate the data to be displayed?
    To get an understanding of what parameters Maretron's displays are capable of showing, and what equipment is necessary for generating the displayed data, please see the attached file, which is entitle...

  19. What are the weights and dimensions of Maretron products?What are the weights and dimensions of Maretron products?


  20. How much current does the Maretron smoke/Heat Detector (part # - SH-449CSTE) draw from a power source?How much current does the Maretron smoke/Heat Detector (part # - SH-449CSTE) draw from a power source?
    The smoke/heat detector requires only 23 mA from a power source while standing by and monitoring for smoke or heat. The current requirements jumps to 51 mA once smoke or heat has been...