Using the N2KAnalyzer how do I recover a device?
The N2KAnalyzer software can restore a devices software using the following method:
Select the affected device(represented by a row with light gray serial number shown), right-click ...
What are the Voltage specifications for each Maretron device?
Maretron
Model
Device
Description
NMEA2000
Operating Voltage
Engine/Battery
Interface
SSC200
NMEA
2000 Solid State Compass HW 1.0
9 t...
How come I can't find a RAA100 rudder angle for display on Maretron's DSM200 or DSM250?
In order to keep the number of Maretron DSM200 and DSM250 display menu items to a minimum (there is a posibility of more than 250 batteries, more than 250 engines, more than 250 rudders, etc.), the di...
How do I set the RAA100 configuration setting called "Gauge Resistance, + to sender" using Maretron's DSM200 or DSM250 display?
You set the RAA100 "Gauge Resistance, + to sender" using Maretron's DSM200 or DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device ...
How do I set the RAA100 configuration setting called "Gauge Resistance, - to sender" using Maretron's DSM200 or DSM250 display?
You set the RAA100 "Gauge Resistance, - to sender" using Maretron's DSM200 or DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device ...
What is the default calibration setting for the RAA100?
The RAA100 default calibration mode is set to accept the American standard resistance values of 240 to 30 ohms (240 ohms representing 60 degrees to port and 30 ohms representing 60 degrees to starboar...
Can I set the RAA100 to accept the European standard for resistance values (i.e. 10 to 180 ohms) using Maretron's DSM200 or DSM250 display?
Yes, it is possible to set the RAA100 to accept European standard resistive sensors using Maretron's DSM200 or DSM250 display. Set the mode using Maretron's DSM200 or DSM250 display in the following w...
Can I set the RAA100 to accept the American standard for resistance values (i.e. 240 to 33 ohms) using Maretron's DSM200 or DSM250 display?
Yes, it is possible to set the RAA100 to accept American standard resistive sensors using Maretron's DSM200 or DSM250 display. Set the mode using Maretron's DSM200 or DSM250 display in the following w...
Is it possible to turn on or off RAA100 transmitted messages (or PGNs)?
Yes, it is possible to turn on and off the RAA100 transmitted messages (or PGNs) using Mareton's DSM200 or DSM250 display. On the display, enter menu mode, scroll to "Configuration…" and press e...
How do I reset the RAA100 to send the factory default messages (or PGNs)?
You reset the RAA100 to transmit the factory default messages using Maretron's DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device...
How come my rudder display doesn't read hard over when the rudder is hard over?
The rudder display may not read hard over even though the rudder is hard over if the resistive sensor is not turning throughout its entire range. You can fix this by either adjusting the resistive sen...
What firmware changes have taken place on the Maretron DSM200?
What firmware changes have taken place on the Maretron DSM200? Firmware updates not long planned for this model. 2011 DSM200 Firmware Versions:
1.15.0 (2006-12-21)
- Added suppor...
What Maretron devices can one configure with the DSM200 display?
DSM200 was designed and released for sale into the marine
market in 2004. It was designed to support Maretron’s envisioned product line
at that time. In the years following 2004 Maretron ...
What is an RAA100?
The RAA100 is a rudder angle adapter that converts an analog resistive sender into digital information, which is then broadcast over the NMEA 2000 where any NMEA 2000 compatible display can show the r...
What information does the RAA100 provide?
The RAA100 provides the the rudder angle.
What messages (or PGNs) does the RAA100 transmit?
The RAA100 transmits the following message (or PGN):
PGN 127245 - Rudder (Fields: 5 - Position)
How do I display the RAA100 rudder angle on Maretron's DSM200 or DSM250 display?
You display the RAA100 rudder angle on a DSM200 or DSM250 in the following way. Enter menu mode, scroll to "Favorite Screen Setup..." and press enter. Scroll to the favorite screen where you would lik...
How do I set the RAA100 rudder number or instance using Maretron's DSM200 or DSM250 display?
You set the RAA100 rudder number or instance using Maretron's DSM200 or DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device Config...
What is the RAA100 configuration setting "operating mode"?
The RAA100 can operate in one of two ways 1) without an analog gauge which is referred to as the "NMEA 2000" mode, and 2) with an analog gauge which is referred to as the "NMEA 2000 & Analog Gauge" mo...
How do I set the RAA100 operating mode using Maretron's DSM200 or DSM250 display?
You set the RAA100 operating mode using Maretron's DSM200 or DSM250 display in the following way. Enter menu mode, scroll to "Configuration…" and press enter. Scroll to "Device ConfigurationR...