There were 4 articles found in this category:
  1. questionUsing the N2KAnalyzer how do I recover a device?
    The N2KAnalyzer software can restore a devices software using the following method: Select the affected device(represented by a row with light gray serial number shown), right-click to highlight the row, select "Update selected device software". A window will prompt you to enter the device' ...

  2. questionWhat firmware changes have taken place on the Maretron FFM100 Fluid Flow Module?
    What firmware changes have taken place on the Maretron FFM100 Fluid Flow Module? Update your device today using the N2KAnalyzer software tool. Version 1.1.1.2: - Added support for single-phase sensors (typically used for non-fuel fluid flow applications) - Added support for Maretron propri ...

  3. questionWhat are the Voltage specifications for each Maretron device?
    Maretron Model Device Description NMEA2000 Operating Voltage Engine/Battery Interface SSC200 NMEA 2000 Solid State Compass HW 1.0 9 to 16 Volts USB100 NMEA 2000 / NMEA 0183 Gateway 9 to 16 Volts DSM200 NMEA 2000 Multi-function Display 9 to 16 Volts GPS100 NMEA 2000 GPS Antenna / ...

  4. questionWhat type of solderless connector is ideal for mating sensor wire to Maretron multi-channel products?
    A #4 Nylon Double-Crimp Insulated Ring Terminal( P/N:WT-651045) is the ideal choice when connecting sensor wire to any of Maretron's multi-channel devices. The following link provides a great color selection to choose from: http://www.wiringproducts.com - Mike Voorhees from Yacht Masters ...