There were 7 articles found in this category:
  1. questionUsing the N2KAnalyzer how do I recover a device?
    The N2KAnalyzer software can restore a devices software using the following method: Select the affected device(represented by a row with light gray serial number shown), right-click to highlight the row, select "Update selected device software". A window will prompt you to enter the device' ...

  2. questionWhat are the Voltage specifications for each Maretron device?
    Maretron Model Device Description NMEA2000 Operating Voltage Engine/Battery Interface SSC200 NMEA 2000 Solid State Compass HW 1.0 9 to 16 Volts USB100 NMEA 2000 / NMEA 0183 Gateway 9 to 16 Volts DSM200 NMEA 2000 Multi-function Display 9 to 16 Volts GPS100 NMEA 2000 GPS Antenna / ...

  3. questionWhat type of information can be viewed on Maretron's display products, and what products are required to generate the data to be displayed?
    To get an understanding of what parameters Maretron's displays are capable of showing, and what equipment is necessary for generating the displayed data, please see the attached file, which is entitled "Maretron Capability Matrix.pdf".

  4. questionWhat type of solderless connector is ideal for mating sensor wire to Maretron multi-channel products?
    A #4 Nylon Double-Crimp Insulated Ring Terminal( P/N:WT-651045) is the ideal choice when connecting sensor wire to any of Maretron's multi-channel devices. The following link provides a great color selection to choose from: http://www.wiringproducts.com - Mike Voorhees from Yacht Masters ...

  5. questionWhat firmware changes have taken place on the Maretron RIM100?
    What firmware changes have taken place on the Maretron RIM100? RIM100 Firmware Versions 1.1.3 (2011-22-04) - Improvements to support Manufacturing. 1.1.2 (2009-11-02) - Corrected a problem where the RIM100 would not always properly indicate an “ON” condition for an AC in ...

  6. questionCan I use the RIM100 to indicate "Water In Fuel"?
    The RIM100 can be used to monitor a Parker/Racor "Water-In-Fuel Detection Kit" (Part Number RK30880E) to indicate water in the fuel filter. First, make sure the RK30880E is properly connected and working (see attachment for wiring diagram). Next, connect a wire between the V1+ terminal on the RI ...

  7. questionWhat are the weights and dimensions of Maretron products?